![Lamborghini Caloreclima ERA 31 BS 130 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/lamborghini-caloreclima/era-31-bs-130/era-31-bs-130_installation-and-maintenance-manual_3472601052.webp)
52
Conversion from LPG to Methane
-
Check the gas pipe – gas valve joint function with a manometer
-
Adjust the burner pressure according to what indicated in the technical data table
-
Seal the pressure adjusting screw replacing the plug
-
Stick the label: “Boiler regulated for METHANE” on the existing one.
BOILER MAINTENANCE
USER INFORMATION
The operations that the user can perform on the boiler are only as follows:
- Check the quantity of water in the boiler and in the plant (at least once a week)
- Unlock the circulators when they have been inactive for over 15 days (turn the main switch off, unscrew the
chromed screw on the circulators and free the rotor with a screwdriver)
- Unlock the safety thermostat and the reset pushbutton
- Check the anode: when the small red knob on the anode is rotated in counter clockwise direction, no water
must leak. If water leaks, the anode has reached an 80% wear. Contact the Technical Service to replace it
If this check is not performed, the water heater guarantee will not be valid anymore, and the water
heater integrity will be impaired.
- In case of doubts, or if the boiler reset operations must be performed more than three times, contact a
qualified technician.
BOILER ELECTRONIC IGNITION
- Open the gas tap
- Set the boiler thermostat to minimum
- Set the boiler adjusting thermostat and the priority thermostat to the desired temperatures
Turn the main switch on
The fan pilot lamp will light up and gas will start exiting from the main burner; at the same time, the igniter
will set the spark. After at most 10 seconds, the igniter will stop and the burner will remain on.
Should any failures be noted during ignition, or if you cannot ignite the boiler after having performed all
operations correctly, contact a qualified technician.
- Check and adjust the clock/room thermostat, if any
- Set the summer/winter switch to the desired position.
IF THE PILOT LAMP LIGHTS UP AND THE FUME THERMOSTAT TRIGGERS WITH BOILER OPERATING AND
REGULARLY CONNECTED TO THE CHIMNEY, CHECK THE CHIMNEY EFFICIENCY
Содержание ERA 31 BS 130
Страница 2: ...2...
Страница 11: ...11 PROGRAMMAZIONE DEL CRONODATARIO...
Страница 28: ...28...
Страница 37: ...37 PROGRAMMING THE HOUR DATE COUNTER...
Страница 54: ...54...
Страница 63: ...63 PROGRAMACI N DEL RELOJ PROGRAMMADOR DIGITAL...
Страница 80: ...80...
Страница 89: ...89 ACERTARO REL GIO PROGRAMADOR...
Страница 106: ...106...
Страница 107: ...107...