Value
Description
Level
d_1
Monday
U / I
d_2
Tuesday
U / I
d_3
Wednesday
U / I
d_4
Thursday
U / I
d_5
Friday
U / I
d_6
Saturday
U / I
d_7
Sunday
U / I
Level: U=user menu - I=installer menu
Weekly programming allows you to define 6 distinct operating
time bands for each day of the week.
Value
Description
Level
d1A
Time slot 1
U / I
d1b
Time slot 2
U / I
d1c
Time slot 3
U / I
d1d
Time slot 4
U / I
d1E
Time slot 5
U / I
d1F
Time slot 6
U / I
Level: U=user menu - I=installer menu
For each band it is possible to define the operating mode (stan-
dard or silenced), the set point, the start and end time and, in
the case of a cascade of water heaters.
For example: by accessing the “d1A” menu, by pressing the
“SET” key and scrolling with the “+” and “-” keys, the values
from “1A1” to “1A9” will appear.
Value
Description
default min max
Unit of
mea-
sure
Note
Level
1A1 Enabling/Disa-
bling time band 1
0
0
1
-
(0=disabled, 1=enabled)
U / I
1A2 Band 1 start time
00
00
23
ora 00:23
U / I
1A3 Time slot 1 starts
00
00
45
min 00, 15, 30, 45
U / I
1A4 Band 1 end time
00
00
23
ora 00:23
U / I
1A5 Band 1 end
minutes
00
00
45
min 00, 15, 30, 45
U / I
1A6 Band 1 operating
mode
2
2
5
-
2:5= (2=ECO, 3=AUTO,
4=BOOSTER, 5=ELEC-
TRIC HEATING)
U / I
1A7 Band 1 setpoint
50
38
75
°C 38:62 / 38:75 (depending
on the mode selected)
U / I
1A8
Enabling/Disa-
bling Silent mode
in band 1
0
0
1
-
(0=disabled, 1=enabled)
U / I
1A9 Unsable
-
-
-
-
-
-
Level: U=user menu - I=installer menu
By pressing the “SET” key again on the parameter to be
modified, its value can be modified using the “+” and “-” keys.
Then press the “SET” key for 3 seconds to confirm (a beep will
confirm the modification) or the “ON/OFF” key to exit the menu.
Carry out the same procedure for time slots 2 (d1b) to 6 (d1F), then
repeat for the following days (d_2=Tuesday, d_3=Wednesday,
d_4=Thursday, d_5=Friday, d_6= Saturday, d_7=Sunday).
Once the programming has been set, it will be possible
to activate or deactivate it via parameter d_0 of the Sch.
The schedule can be more easily set via APP.
Note
: between one time slot and the next, the appliance goes
into stand-by.
2.8.4 FAn MENU - FAN AND SILENT MODE SETTING
In this setting it is possible to activate the “silent mode” (for
example during the night) which allows a reduction in the noise
of the appliance; in this condition the performance in terms of
water heating speed may be lower.
To set the fan speed parameter, access the “Fan” menu by
pressing the “SET” key.
Value
Description
Unit of
measure default min
max
Level
F01 Enable silent mode function
(0=disabled, 1=enabled)
-
0
0
1
U / I
F02 Fan speed in FAN mode
%
100 10
100
I
F03 Silent mode fan speed
%
30 10
100
I
Level: U=user menu - I=installer menu
To set the fan speed in FAN mode, select the F02 value. By
pressing the “SET” key again, the default value of the fan
speed will appear.
To enable the silent function, select the F01 value, pressing
the “SET” key again the value “0” will appear (it means that
the fan works in default conditions), to activate the silent mode
press the “+” and “ -” to bring the value to “1”. Press the “SET”
key to confirm (a beep will confirm the modification) and
the “ON/OFF” key to exit the menu.
To set the fan speed in silent mode instead, select the F03
value. By pressing the “SET” key again, the default value
of the fan speed will appear. Decreasing the % value will de-
crease the noise.