DORA TECH
90 LT - 120 LT
cod. 3540000800 - Rev. 02 - 09/2023
100
EN
fig. 58- Example of condensate drain connection with a trap
6.8 ELECTRICAL CONNECTIONS
The device is equipped with a power cable with Schuko plug
to be connected to the power grid via a suitable socket (fig. 59
fig. 59 - Schuko socket
fig. 60 - Unit plug
ATTENTION
The device must be installed in
compliance with the regulations
on electrical systems in force in
the country of installation.
OBLIGATION
Connect the device to an efficient
grounding system.
PROHIBITION
Do not use extension cords or
adapters.
ATTENTION
For connection to mains and
safety devices, comply with the
IEC 60364-4-41 standard.
ATTENTION
Fixed devices are not equipped
with means of disconnection
from the mains with a separation
of the contacts on all poles ca-
pable of guaranteeing complete
disconnection in the
overvolt-
age category III
, the instruc-
tions indicate that the means of
disconnection must be integrat-
ed in the fixed wiring in compli-
ance with the wiring regulations.
ATTENTION
The device must be protected by
an adequate differential switch.
The type of differential switch
should be selected by assess-
ing the type of electrical devices
used by the system as a whole.
ATTENTION
DO NOT TAMPER WITH THE
POWER CORD.
If the power supply cable is dam-
aged, it must be replaced by the
manufacturer or the technical as-
sistance service or in any case
by a person with similar qualifi-
cations, in order to prevent any
risk.