cod. 3541T620 - Rev. 05 - 04/2022
106
EN
DORA
90 LT - 120 LT
ATTENTION
In case of replacement of the
fuse, replace it with a new de-
layed-type one of 5 A 250V IEC
60127-2/II (T5AL250V) certified
(refer to par. 7.1 on page 145).
ATTENTION
Before carrying out any repairs
to the product, carefully read the
wiring diagram shown in chapt.
“6.9 ELECTRICAL DIAGRAM” on
page 139 and also refer to the
inside the product itself.
►
USE INTENDED BY THE MANUFACTURER
Definition
Air heat pump for the production of domestic hot water
The device covered in this manual has been designed for do-
mestic use in accordance with the requirements provided for in
the reference standards indicated in paragraph 1.4.
Moreover, to meet the design and safety features:
• the device must be used according to the instructions and
limits of use indicated in this manual;
• the procedures indicated in this user manual must be fol-
lowed;
• ordinary maintenance must be carried out periodically in the
times and in the manner indicated;
• extraordinary maintenance must be performed promptly in
case of need.
In consideration of the design features, it is not possible to use
the device for other purposes, nor can the manufacturer envis-
age other ways of use.
PROHIBITION
Using the product for purposes
other than that specified is pro-
hibited. Any other use is consid-
ered inappropriate and is not per-
mitted.
►
REASONABLY FORESEEABLE MISUSE
Reasonably foreseeable misuses are listed below:
• no aeraulic connection with the external environment
(ref. par. 6.6 on page 134)
;
• introduction of liquid or solid materials containing chemically
aggressive substances;
• use the equipment differently from what is envisaged in par-
agraph “USE INTENDED BY THE MANUFACTURER” and
as indicated in par. “5.3 TECHNICAL FEATURES” on page
131.
Any use other than the one envisaged must be previously au-
thorised in writing by the Manufacturer.
In the absence of such written authorisation, the use is to be
considered “
improper use
”; therefore
LAMBORGHINI
de-
clines all responsibility in relation to any damage caused to
things or people and deems any type of guarantee on supply
null and void.
NB! The manufacturer declines any liability
for uses different from those for which the
equipment is designed, and for any installa-
tion errors or improper use of the unit.
►
INTENDED USE OF THE DEVICE
The device is intended to be used in a domestic environment
within the limits of allowed environmental conditions indicated
in chapter 6.
►
RISK FROM INADEQUATE
MAINTENANCE OR REPAIR
EXPERT
TECHNI-
CIAN
R290
Any intervention on the de-
vice, including disposal, must
be performed by qualified per-
sonnel with a suitable Refrig-
eration Technician's Licence
aimed at the knowledge and
management of systems con-
taining HC type gases such as
R290 (Propane).
PROHIBITION
Never try to carry out mainte-
nance work or repairs on the
product yourself.
•
Have a qualified technician immediately remove faults and
damage.
•
Comply with the prescribed maintenance intervals.
Содержание DORA 120 LT
Страница 2: ...IT 3 ES 53 EN 105...
Страница 29: ...29 cod 3541T620 Rev 05 04 2022 IT DORA 90 LT 120 LT fig 21 fig 22 5 2 DATI DIMENSIONALI fig 23 fig 24...
Страница 79: ...79 c d 3541T620 Rev 05 04 2022 ES DORA 90 LT 120 LT fig 21 fig 22 5 2 DATOS DIMENSIONALES fig 23 fig 24...
Страница 102: ...c d 3541T620 Rev 05 04 2022 102 ES DORA 90 LT 120 LT...
Страница 129: ...129 cod 3541T620 Rev 05 04 2022 EN DORA 90 LT 120 LT fig 21 fig 22 5 2 DIMENSIONAL DATA fig 23 fig 24...