65
FLUE EXHAUST INSTALLATION
Attention: Use only air intake/ fumes evacuation kit produced by Lamborghini Caloreclima.
CONCENTRIC FLUE PIPE
Fit the concentric elbow pipe positioning it on the desired direction and insert on it the sealing gasket. Fit the air intake
and flue pipes, observing the distances indicated on the installation scheme. The flue pipe should slope slightly outward.
DOUBLE FLUE PIPE
Installing an elbow to connect the boiler to the chimney will cause a drop in pressure. The values set out in the
table below indicate the necessary modifications to the length of the linear pipes.
TYPE OF INSTALLATION
ELBOW FITTED AT 90
°
ELBOW FITTED AT 45
°
Flue exhaust for fan-forced draught version (B22)
Concentric flue exhaust
Double flue pipe (intake/exhaust)
0,6 mt.
1 mt.
0,6 mt.
0,3 mt.
0,5 mt.
0,3 mt.
FLUE PIPE FOR FAN-FORCED
DRAUGHT VERSION (B22)
SELECTING THE RIGHT AIR
DIAPHRAGM
(A)
LAMBY 20
LAMBY 24
Flue exhaust for fan-forced draught version (B22)
Ø78 mm.
Ø 77 mm
Concentric flue exhaust from 0.35m to 1m
Ø78 mm.
Ø 77 mm
Concentric flue exhaust from 1m to 3m
Ø82 mm. Standard Ø90 mm. Standard
Double flue pipe (intake/outlet)
Ø82 mm. Standard
Double flue pipe (intake/outlet) from 0 m to 12 m
Ø 77 mm
Double flue pipe (intake/outlet) from 12 m to 60 m
Ø90 mm. Standard
FLUE EXHAUST FOR FAN-FORCED DRAUGHT
VERSION (B22): max length 13 m. After 5 m. it is
advisable to install a condensation collection kit.
CONCENTRIC FLUE EXHAUST: max length 3 m
DOUBLE FLUE PIPE max. length
( delivery) 16,5 m. (LAMBY 20) and 60 m.
(LAMBY 24 max. 40 m. flue pipe). After 5 m. it is take