1.3.3 REGULATION
A. A regulation of less than 0.1 % of the maximum rated output is maintained over the
entire range of the input line voltage given in table 1.1
B. Voltage Mode: A load change of 100% (from full load to no load) will cause an output
voltage deviation of less than 0.1% of maximum output voltage.
C. Current Mode: A load change of 100% (from full load to a short) will cause an output
current deviation of less than 0.1% of maximum output current.
250
250
250
EMS 600-1.6
EMS 600-3.3
EMS 600-4
1000
2000
2500
150
150
150
EMS 300-3.5
EMS 300-6
EMS 300-8
1000
2000
2500
120
120
120
EMS 150-7
EMS 150-13
EMS 150-16
1000
2000
2500
100
100
100
EMS 100-10
EMS 100-20
EMS 100-25
1000
2000
2500
100
100
100
100
EMS 80-7.5
EMS 80-13
EMS 80-25
EMS 80-30
600
1000
2000
2500
100
75
75
75
EMS 60-10
EMS 60-18
EMS 60-33
EMS 60-40
600
1000
2000
2500
100
75
75
75
EMS 40-15
EMS 40-25
EMS 40-50
EMS 40-60
600
1000
2000
2500
100
75
75
75
EMS 30-20
EMS 30-33
EMS 30-65
EMS 30-80
600
1000
2000
2500
100
75
75
75
EMS 20-30
EMS 20-50
EMS 20-100
EMS 20-125
600
1000
2000
2500
100
75
75
75
EMS 10-60
EMS 10-100
EMS 10-200
EMS 10-250
600
1000
2000
2500
100
75
75
75
EMS 7.5-75
EMS 7.5-130
EMS 7.5-250
EMS 7.5-300
600
1000
2000
2500
Max. Ripple (mV)p-p Carrier
Model Number
Watts
Table 1.2: Ripple for Single Phase
83-473-000 Revision J
1 - 3