2.2.1.3.

 

Amplifier

 

Module

 

&

 

DSP:

 

Gain

 

Control

 

When

 

the

 

gain

 

control

 

is

 

at

 

its

 

maximum

 

position,

 

the

 

maximum

 

input

 

voltage

 

before

 

clipping

 

is

 

5Vrms

 

(+/-

 

7V

 

peak).

 

This

 

value

 

increases

 

proportionally

 

by

 

turning

 

back

 

the

 

gain

 

control.

 

In

 

the

 

12

 

o’clock

 

position,

 

the

 

input

 

signal

 

is

 

reduced

 

by

 

6dB.

 

Therefore

 

the

 

maximum

 

input

 

voltage

 

before

 

clipping

 

increases

 

to

 

10Vrms

 

(+/-

 

14V

 

peak)

 

accordingly.

 

The

 

Gain

 

Control

 

is

 

located

 

in

 

the

 

upper

 

middle

 

of

 

the

 

DSP

 

Control

 

Panel:

 

2.2.1.4.

 

Amplifier

 

Module

 

&

 

DSP:

 

Status

 

Indicators

 

In

 

the

 

upper

 

left

 

corner

 

of

 

the

 

Control

 

Panel

 

you

 

will

 

find

 

4

 

coloured

 

signal

 

LED

 

displays

 

as

 

status

 

indicators

 

of

 

the

 

amplifier

 

module.

 

Their

 

meanings

 

are:

 

www.lambda-labs.com 

!

13

Danger:

  RISK  OF  ELECTRIC  SHOCK!  Use  grounded  mains  only!  Use  undamaged  cables  and 

connectors only! Do NOT insert anything other into the Powercon connectors than Powercon plugs! 
Keep the connectors away from water and excessive humidity!

R

DANGER!

Caution:

 

The mains POWERCON connectors are not suitable for powering up or down the system and 

so  should  not  be  plugged  or  unplugged  while  under  voltage!  Always  connect  the  POWERCON  plug 
FIRST, THEN connect the Schuko plug (or other Standard 3 Pin Power Plug) to the AC power

 

socket

.

 

Follow these steps in a reverse order to power

 

down the system! 

R

CAUTION!

Caution:

 

+/-

15Vpeak (~+22dBu) at the input shouldn’t to be exceeded under any circumstances! 

R

CAUTION!

Содержание CX-1A

Страница 1: ...CX 1A CX 1B Manual Version 1 2 CX 1A CX 1B Manual Version 1 2 05 2020 2020 Lambda Labs All rights reserved This manual is optimized to save paper and to print 2 pages per DIN A4 sheet...

Страница 2: ...SP Powercon Mains 12 2 2 1 3 Amplifier Module DSP Gain Control 13 2 2 1 4 Amplifier Module DSP Status Indicators 13 2 2 1 5 Amplifier Module DSP Selecting Presets 14 2 2 1 6 Amplifier Module DSP Prese...

Страница 3: ...Lambda Labs Professional Acoustics CX 1A B Manual NOTES www lambda labs com 2...

Страница 4: ...l information in this manual has been prepared to the best knowledge and with the utmost care Lambda Labs can not guarantee the accuracy of the documentation in all cases Lambda Labs disclaims any lia...

Страница 5: ...g statutory provisions and safety regulations Qualified operators The operation as well as the planning of the setup may only be carried out by qualified personnel who are familiar and experienced wit...

Страница 6: ...ng the entire installation process Always keep watching all rigging components and connection joints during the uplifting procedure Stop the uplifting procedure if any uncertainty occurs Lambda Labs r...

Страница 7: ...ated rigging system please contact the Lambda Labs technical support and wait for further instructions Do NOT repair or exchange speaker parts or rigging components by yourself and without support of...

Страница 8: ...011 Mechanical Safety DIN 18800 Mechanical Structure BGV C1 DGUV Regulation 17 18 Mechanical Standard applied in Germany WEEE Declaration Disposal Electrical and electronic devices must be disposed of...

Страница 9: ...DAC 48kHz sample rate Frequency Response 80 20 000Hz 3dB Coverage Angle 100 horizontal x 100 vertical Monitor Angle 35 Crossover Frequency 2000Hz Sensitivity 94dB 1W 1m Connection XLR in out Powercon...

Страница 10: ...the loudspeaker with various rigging equipment Therefore the loudspeaker can be flown vertically horizontally and upside down Refer to Chapter 2 2 4 as well Chapter 2 2 4 b Handle Recessed handles are...

Страница 11: ...aker can be tilted down or upwards by adjusting the angle in 4 5 steps The maximum possible tilt angle is 13 5 The stand adapter is suitable to use with a stand distance rod tube diameter of 35mm Lamb...

Страница 12: ...2 2 1 5 Chapter 2 2 1 6 b DIN 912 M4 Screws To protect the control panel from unauthorized access an optional module cover can be installed To do this the 4 upper M4 screws of the module must be remo...

Страница 13: ...ly The grey Powercon connector at the right side provides the power supply link www lambda labs com 12 Danger The amplifier module can develop excessive heat Do NOT touch the surface of the amplifier...

Страница 14: ...4 coloured signal LED displays as status indicators of the amplifier module Their meanings are www lambda labs com 13 Danger RISK OF ELECTRIC SHOCK Use grounded mains only Use undamaged cables and con...

Страница 15: ...to lower the temperature to an uncritical level again When playing music this protective mechanism should only appear if the ambient temperature is very high and or the equipment is exposed to direct...

Страница 16: ...read the MF 15A manual The Crossover Mode 140Hz has a 24dB oct Linkwitz Riley high pass filter at 140Hz Accordingly the subwoofer should have a 24dB oct Linkwitz Riley low pass filter characteristic a...

Страница 17: ...he corners and follow an X order to unmount the other screws to avoid excessive stress in the Amplifier Module s heatsink 2 Put the Module Cover S over the Control Panel area and reinsert the removed...

Страница 18: ...Speaker Flange for safe installation 2 Lift the loudspeaker slightly to release the locking mechanism of the Adjustable Speaker Flange tilt mechanism Always support and secure the loudspeaker sideway...

Страница 19: ...and damage the speaker surface www lambda labs com 18 Ratchet or electric screwdriver HEX BIT Number 6 Wrench Size 6mm R Danger Do NOT use the 10mm Eye Bolt as a rigging item to fly the speaker with i...

Страница 20: ...be used for all speakers from the CX and TX Series It can be combined with the with the Vari Clamp The T Bracket is preassembled and available in 2 versions of the EPS System M Mobile and I Installati...

Страница 21: ...Lambda Labs Professional Acoustics CX 1A B Manual T Bracket www lambda labs com 20 Mobile Version M Installation Version I Mobile Version M Installation Version I T Bracket Vari Clamp...

Страница 22: ...ket is preassembled and available in 2 versions of the EPS System M Mobile and I Installation version The installation version provides additional tamper proof properties to protect the components fro...

Страница 23: ...rsion only The installation version provides tamper proof properties to protect the components from unauthorized access The Half Bracket can be combined with the Main Carrier to extend the fixing area...

Страница 24: ...Do not use ANY other cleaning supplies on these areas We advice against the use of pressure water cleaning the Lambda Labs Loudspeakers and rigging parts in general High pressure cleaning is at your o...

Страница 25: ...Lambda Labs Professional Acoustics CX 1A B Manual 2 4 Dimensions www lambda labs com 24 Dimensions mm Weight 8 4 kg 18 5 lbs 7 2 kg 15 9 lbs 320 253 258 371 376 CX 1A 371 376 CX 1B 300 253 258...

Отзывы: