6
AC Input Connection Procedure
First connect a shore ground lead (for sizing use table on page 4) to the pin marked
6
on the terminal block
TB1
. Then connect the ship
ground lead to the pin marked with a
GROUND
symbol on the terminal block
TB1.
Enclosure’s stud located by the input terminal block may also be used for connecting the ship ground lead. Run
the input AC power wiring to terminals marked
1, 4
or
5
(depending on the input voltage)
on the terminal block
TB1.
AC Output Connection Procedure
Run the equipment AC wiring to terminals marked
X1, X4
or
X5
(depending on the output voltage)
on the
terminal block
TB2.