background image

1.6.2   Fitting & Use

After conducting the “Brief Check'' as instructed in Paragraph 1.6.1 , follow the donning methodology as described below:

a) Harness:

 

Don the apparatus like you wear a Jacket. Make sure no harness or hose is twisted. Adjust the shoulder straps for a tight but comfortable fit. Close the buckle of the 

waist belt and fasten the strap in a comfortable way (Figure 15).

1

2

3

4

Figure 15 Donning the back frame

b) Cylinder valve:

 Push the “OFF'' button of the second stage Regulator (Figure 1 & Figure 7)

c) 

Open slowly the cylinder valve by turning counterclockwise 

until it is fully open

. Listen the whistle sound and check the pressure gauge indication to be equal or more than 

80% of the rated filling pressure, i.e. 240-300bar (Figure 16).

Figure 16 Vessel pressure checking

WARNING: TAKE EXTRA CARE TO HAVE THE CYLINDER VALVE FULLY OPENED DURING USE!

j) 

Doff the 

face piece

 and reassemble the 

second stage regulator

 with the 

first stage regulator

 by the fast joint (Figure 14). The Self-Contained Breathing Apparatus is now 

readily checked and it can be either used or packed for storage.

Figure 14 

Assembling the Second Stage Regulator with the first stage regulator by the fast joint.

LALIZAS

Содержание 71327

Страница 1: ...71327 SELF CONTAINED BREATHING APPARATUS 6L SOLAS MED INSTRUCTIONS OF USE 71328 SELF CONTAINED BREATHING APPARATUS 9L SOLAS MED 0098 L A L I Z A S...

Страница 2: ...g Whistle is so designed that when pressure reduces below 50 60bar it operates providing a continuous sound of pressure level 90dB A warning the user that the air is dropping down Moreover the First S...

Страница 3: ...letConnector andEN144 2 RespiratoryProtectiveDevices GasCylinderValves OutletConnections More specifically the inlet and outlet connections on the pressure vessel valve are respectively in accordance...

Страница 4: ...ator on demand valve and the full face mask The joint of the second stage regulator to the face mask provides a capability of rotationby360 foreasierconnectionandmorecomfortablefitting Aplug ininterfa...

Страница 5: ...nder valve e After checking leak tightness bring the Second Stage Regulator in mouth and inhale to check the operability of the on demand valve Figure 9 After inhaling the air pressure willdropcausing...

Страница 6: ...econd stage regulator with the face piece i Plug the tube entrance with your finger and inhale The face piece should deform towards your face as a sign of face piece leak tightness Figure 13 In case t...

Страница 7: ...Open slowly the cylinder valve by turning counterclockwise until it is fully open Listen the whistle sound and check the pressure gauge indication to be equal or more than 80 oftheratedfillingpressure...

Страница 8: ...7 II Placethelowerstrapoveryourhead Figure17 III Pullthehead netontopofthefacepiece Figure18 IV Insertthefacepieceonyourfacetofitthesealingedgeandusetheheadnetlooptoplacethehead netoverthehead Figure1...

Страница 9: ...breathing take a breath and hold it Feel the air flow stopping and then insert your finger in the face piece seal as shown in Figure 21 This actionshouldforcethedemandvalvetoprovidesteadyflowagain Rem...

Страница 10: ...iecefollowingthenextsteps Step1 Cleanthefacepiecethoroughlywithwarmfreshwater maximumtemperature 43 C andNeutralsoap Step2 Rinsethemaskthoroughlywithfreshwater Step3 Afterwardsshakethemasktoremovether...

Страница 11: ...trapsandbuckles Visualchecking 1 ConductavisualcheckintheSCBAforexternaldamageswearandmaterialfatigue 2 Dontheapparatusandcheckshoulderstrapsandwaistbeltbyfasteningandlooseningthem Dofftheapparatus 3...

Страница 12: ...71327 71328 Product code Product name Type Air supply Warning pressure Working pressure Total Rated duration Cylinder Volume Cylinder material Weight Storage temperature Operating temperature Storage...

Отзывы: