1.6.2 Fitting & Use
After conducting the “Brief Check'' as instructed in Paragraph 1.6.1 , follow the donning methodology as described below:
a) Harness:
Don the apparatus like you wear a Jacket. Make sure no harness or hose is twisted. Adjust the shoulder straps for a tight but comfortable fit. Close the buckle of the
waist belt and fasten the strap in a comfortable way (Figure 15).
1
2
3
4
Figure 15 Donning the back frame
b) Cylinder valve:
Push the “OFF'' button of the second stage Regulator (Figure 1 & Figure 7)
c)
Open slowly the cylinder valve by turning counterclockwise
until it is fully open
. Listen the whistle sound and check the pressure gauge indication to be equal or more than
80% of the rated filling pressure, i.e. 240-300bar (Figure 16).
Figure 16 Vessel pressure checking
WARNING: TAKE EXTRA CARE TO HAVE THE CYLINDER VALVE FULLY OPENED DURING USE!
j)
Doff the
face piece
and reassemble the
second stage regulator
with the
first stage regulator
by the fast joint (Figure 14). The Self-Contained Breathing Apparatus is now
readily checked and it can be either used or packed for storage.
Figure 14
Assembling the Second Stage Regulator with the first stage regulator by the fast joint.
LALIZAS