LAISAI LS526 Скачать руководство пользователя страница 6

 

4.10 Slope function key                                     

a) Place the instrument horizontally   

Press slope function key, the instrument enter into double axis slope, the default is X axis slope, X LED is on, Y axis is 

not leveling, press slope left/right moving key could make slope adjustment, short press slope function key could switch 

X/Y direction, long press to exit slope function.   

Long press slope function key, the instrument enter into single axis slope, the default is X axis slope, X LED is on, Y axis 

is self-leveling, Y LED flash. Press slope left/right key could make slope adjustment. Short press slope function could 

switch slope direction X/Y, long press to exit slope function.   

 

b) Place the instrument transversely   

Press slope function key, the instrument enter double axis slope, default is X axis slope, X direction LED is on, Y axis is 

not leveling, press slope left/right key could make slope adjustment, press slope function key could switch X/Y direction, 

long press to exit slope function.   

Long  press  slope  key,  the  instrument  will  enter  single  axis  slope,  the  default  is  X  axis  slope,  X  LED  is  on  ,Z  axis  is 

self-leveling, Y direction LED is flash, press slope left/right moving key could make slope adjustment, long press to exit 

slope adjustment function.   

 

 

 

 

 

 

 

 

4.11 Self-leveling key     

 

Press this key, the instrument will enter into self-leveling status, the instrument is in TILT alarming status, press this key, 

the instrument exit alarming status, and make leveling, after leveling, TILT mode still remains, when the instrument is in 

slope adjustment status, press this key, the instrument will exit slope adjustment and enter into self-leveling status.   

 

 

4.12 Remote shielding key                 

Power on and the remote function is on default, the remote status indication LED is on, press this key, the LED is off, 

the instrument will not receive the signal of remote control.   

 

4.13 Remote control keypad   

 

 

 

 

 

 

 

 

 

 

 

 

Sleep key                 

a) Press sleep key, the instrument enter or exit sleep status. 

b) The instrument enter sleep status, power LED flash interval, if the instrument will not exit sleep status in 30 minutes, 

Self-leveling key 

Slope function key 

Area scanning function key 

Area scanning moving key 

ON/OFF key 

Self-calibration direction select key 

Slope function key 

Rotation speed switch key   

Calibration confirmation key 

Self-calibration adjustment key 

Z direction 

Y direction 

X direction 

Содержание LS526

Страница 1: ...ronic auto leveling when beyond the range the instrument stops rotating and sound indication 360 rotary laser able to work horizontally and vertically Able to set different rotation speed and area scanning angle Able to unbalance alarm in TILT mode The instrument stops rotating when knocked in order to make sure work accurately Slope mode function could set single axis or double axis slope Accurac...

Страница 2: ...ording to polarity direction then fix the battery box on the instrument b Fix the rechargeable battery on the instrument 4 2 Charging to rechargeable battery Central 5 8 screw thread Side 5 8 screw thread Battery cover screw Remote receiving tube Battery cover Laser output window Hand wheel Rotary head Operation keypad ...

Страница 3: ...nstrument Note a When the power LED is flashing the battery is in low voltage It can extend the life of the battery when charging the battery as the battery is use up b Charging once to rechargeable battery every two or three months since the instrument leaving factory 4 3 Placement of the instrument Instrument in horizontal placement a Place on a horizontal platform directly b Connect with the tr...

Страница 4: ...eration keypad Slope move leftwards key TILT mode key Self leveling key X direction slope LED Y direction slope LED Remote status LED TILT mode LED Slope function key Remote shielding key Area scanning dot move clockwise key Area scanning dot move anti clockwise key Power LED On off key Area scanning function Rotation speed set key Slope move rightwards key ...

Страница 5: ...witched to low speed and the rotation speed is 200rpm 4 7 Area Scanning function key a When the instrument is rotating press this key to enter the area scan mode the instrument enter into big area scanning status press this key again enter into small area scanning status press this third time enter into dot status the area scanning order will be switched as follows 4 8 Area scanning moving key a U...

Страница 6: ...X LED is on Z axis is self leveling Y direction LED is flash press slope left right moving key could make slope adjustment long press to exit slope adjustment function 4 11 Self leveling key Press this key the instrument will enter into self leveling status the instrument is in TILT alarming status press this key the instrument exit alarming status and make leveling after leveling TILT mode still ...

Страница 7: ... by 90 degrees in turn after the instrument is auto leveling mark the point of intersection of the laser line and the vertical line as point B C and D separately 4 Measure the maximal distance h between two points which among point A B C D 5 If h 3mm the accuracy is OK If 3mm h 20mm the accuracy is beyond tolerance the user could adjust and calibrate the accuracy If h 20mm the accuracy is beyond t...

Страница 8: ...key on remote control Y calibration LED on instrument keypad flash the instrument will enter into Y direction calibration c Press self calibration adjustment on remote control the laser line move up and down until it coincides with dot O 4 Calibration confirmation When X direction and Y direction confirmation are finished press self calibration confirmation key calibration LED is off calibration v...

Страница 9: ... Parameter Laser wavelength LS526 635nm LSG526 532nm Laser class ClassⅡ Ⅲ Output range LS526 600m LSG526 400m Rotating speed 600 rpm Area scanning angle Big area scanning small area scanning dot Accuracy 0 75mm 10m Leveling range 5 Working temperature 10 45 ...

Страница 10: ...nt Do not attempt to disassemble the instrument and the unprofessional disassembly will result in the damage of instrument Keep the cleanness of instrument especially the laser output window and remove dust by the gentle operation of soft clean cloth Take the batteries out when the instrument is not in use for a long time and keep the instrument in the carrying case when it is unused Although the ...

Отзывы: