background image

 

Power LED:   

Lighted LED means power-on 

Extinguished LED means power-off 

Flashing LED means low battery voltage 

 

TILT mode LED:

   

Flashing slowly (1Hz): The instrument enter into TILT preparation status   

Lighted constantly: The status of TILT function become effective 

Flashing quickly: The instrument is in TILT alarming status 

Extinguished: The instrument exit from TILT status 

 

Slope axis LED: 

Both X and Y LEDs, the LEDs are on means this axis is in the slope set status.     

Remote control indication LED   

      ON: remote control function is on, and able to use the remote control to operate the instrument. 

      OFF: remote control function is off, could only operate the instrument with keypad   

 

4.5 on/off key 

a) Press on/off key, the instrument is power on, the power LED is lighted. 

b) The instrument is in auto-leveling status when the power is on. Then rotating in high speed after auto leveling, the 

rotating speed is 500rpm.   

 

4.6 Rotation speed set key             

After the instrument is self-leveling, the instrument is in high speed rotation status, the rotation speed is 500rpm.Press 

rotation speed set key, the rotation speed is switched to low speed, and the rotation speed is 200rpm.   

 

4.7 Area Scanning function key           

a)  When  the  instrument  is  rotating,  press  this  key  to  enter  the  area  scan  mode,  the  instrument  enter  into  big  area 

scanning status, press this key again, enter into small area scanning status, press this third time, enter into dot status, 

the area scanning order will be switched as follows,   

 

 

 

 

 

4.8 Area scanning moving key                 

 

a)Under  area  scanning  status,  press  area  scanning  moving  key,  single  press  to  move  slowly,  long  press  to  move 

continuously.   

 

b) Under dot status, press area scanning moving key, single press to move slowly, long press to move continuously.   

 

4.9 TILT mode key 

       

 

a) Press TILT key to exit or enter TILT mode(the instrument will power on and enter into TILT mode automatically).   

b) After entering into TILT mode, the status LED flash slowly (1Hz), after leveling, the head rotates, and TILT function is 

activated after 30 seconds, the status LED is always  on, the instrument will sound TILT alarming once shocked, the 

status LED flash quickly, the laser stop rotating and start flashing, the instrument will not self-leveling, press TILT key 

again, exit TILT status and enter into self-leveling status. 

c) If the instrument is under double axis slope working status, TILT key is invalid.   

 

Big area scanning 

Big area scanning 

Dot 

Содержание LS526

Страница 1: ...ronic auto leveling when beyond the range the instrument stops rotating and sound indication 360 rotary laser able to work horizontally and vertically Able to set different rotation speed and area scanning angle Able to unbalance alarm in TILT mode The instrument stops rotating when knocked in order to make sure work accurately Slope mode function could set single axis or double axis slope Accurac...

Страница 2: ...ording to polarity direction then fix the battery box on the instrument b Fix the rechargeable battery on the instrument 4 2 Charging to rechargeable battery Central 5 8 screw thread Side 5 8 screw thread Battery cover screw Remote receiving tube Battery cover Laser output window Hand wheel Rotary head Operation keypad ...

Страница 3: ...nstrument Note a When the power LED is flashing the battery is in low voltage It can extend the life of the battery when charging the battery as the battery is use up b Charging once to rechargeable battery every two or three months since the instrument leaving factory 4 3 Placement of the instrument Instrument in horizontal placement a Place on a horizontal platform directly b Connect with the tr...

Страница 4: ...eration keypad Slope move leftwards key TILT mode key Self leveling key X direction slope LED Y direction slope LED Remote status LED TILT mode LED Slope function key Remote shielding key Area scanning dot move clockwise key Area scanning dot move anti clockwise key Power LED On off key Area scanning function Rotation speed set key Slope move rightwards key ...

Страница 5: ...witched to low speed and the rotation speed is 200rpm 4 7 Area Scanning function key a When the instrument is rotating press this key to enter the area scan mode the instrument enter into big area scanning status press this key again enter into small area scanning status press this third time enter into dot status the area scanning order will be switched as follows 4 8 Area scanning moving key a U...

Страница 6: ...X LED is on Z axis is self leveling Y direction LED is flash press slope left right moving key could make slope adjustment long press to exit slope adjustment function 4 11 Self leveling key Press this key the instrument will enter into self leveling status the instrument is in TILT alarming status press this key the instrument exit alarming status and make leveling after leveling TILT mode still ...

Страница 7: ... by 90 degrees in turn after the instrument is auto leveling mark the point of intersection of the laser line and the vertical line as point B C and D separately 4 Measure the maximal distance h between two points which among point A B C D 5 If h 3mm the accuracy is OK If 3mm h 20mm the accuracy is beyond tolerance the user could adjust and calibrate the accuracy If h 20mm the accuracy is beyond t...

Страница 8: ...key on remote control Y calibration LED on instrument keypad flash the instrument will enter into Y direction calibration c Press self calibration adjustment on remote control the laser line move up and down until it coincides with dot O 4 Calibration confirmation When X direction and Y direction confirmation are finished press self calibration confirmation key calibration LED is off calibration v...

Страница 9: ... Parameter Laser wavelength LS526 635nm LSG526 532nm Laser class ClassⅡ Ⅲ Output range LS526 600m LSG526 400m Rotating speed 600 rpm Area scanning angle Big area scanning small area scanning dot Accuracy 0 75mm 10m Leveling range 5 Working temperature 10 45 ...

Страница 10: ...nt Do not attempt to disassemble the instrument and the unprofessional disassembly will result in the damage of instrument Keep the cleanness of instrument especially the laser output window and remove dust by the gentle operation of soft clean cloth Take the batteries out when the instrument is not in use for a long time and keep the instrument in the carrying case when it is unused Although the ...

Отзывы: