CL4490 Hardware Integration Guide
Version 1.0
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/ramp
7
Laird Technologies
POWER SETTINGS (Input Voltage: 12 v DC)
Transmit – Full Duty Cycle
Max Power Setting
Current (mA)
dBm mW
Low
157
10
10
Quarter
225
23
200
Half
280
26
400
Full
365
28
743
Receive – Transceiver in Idle
Max Power Setting
Current (mA)
Low
50
Quarter
50
Half
50
Full
50
ENVIRONMENTAL
Temperature (Operational)
-40° C to 80° C
Temperature (Storage)
-50° C to +85° C
Humidity (Non-Condensing)
10% to 90%
PHYSICAL
Dimensions
4.4 x 2.7 x 1.4 inches
Weight
6 oz. (170 g)
CERTIFICATIONS
FCC Part 15.247
CL4490-200: KQLAC4490-100
CL4490-1000/PRO: KQLAC4490
Industry Canada (IC)
CL4490-200: 2268C-AC4490
CL4490-1000/PRO: 2268C-AC44901000
Caution! ESD Sensitive Component. You must use proper ESD precautions when
handling this device to prevent permanent damage.
External ESD protection is required to protect this device from damage as required
to pass IEC 61000-4-2 or ISO 10605 based on end system application.