Table 10: Product Matrix 

Part Number 

AC4490-1x1 

AC4490-200 

AC4490-1000 

Size 

1.0" x 1.0" x 0.125" 

1.9" x 1.65" x 0.20" 

1.9" x 1.65" x 0.20" 

Range 

Up to 1 mile 

Up to 4 miles 

Up to 20 miles 

Throughput 

32 Kbps 

32 Kbps 

32 Kbps 

Current Draw RX 

28 mA 

30 mA 

30 mA 

Current Draw TX 

80 mA 

106 mA 

1300 mA 

Current Draw (Sleep 
Mode) 

15 mA / 3 mA 

19 mA / 6 mA 

19 mA / 6 mA 

Chan 

48 

48 

32 

Band 

900 MHz 

900 MHz 

900 MHz 

3.3V 

Yes 

Yes 

Yes 

Unit 

Module 

Module 

Module 

Approvals 

None;   
needs OEM end approval 

FCC / IC 

FCC / IC 

API 

Yes 

Yes 

Yes 

Integrated Antenna 
Available 

No 

Yes 

No 

 

 

 

Содержание AC4490

Страница 1: ...Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 wireless support lairdtech com www lairdtech com ramp AC4490 Hardware Integration Guide Version 4 6...

Страница 2: ...owney 4 5 4 Aug 2014 Added Approved Antenna List Chris Downey 4 6 18 May 2017 Removed references to EOL part numbers Jonathan Kaye FCC Notice WARNING This device complies with Part 15 of the FCC Rules...

Страница 3: ...est 12 RSSI 13 UP_Reset 13 CMD Data 14 AD In 14 In Range 14 Serial Interface 14 Serial Communications 14 Asynchronous Operation 14 Parity 14 Serial Interface Baud Rate 15 OEM Host Data Rate 16 Radio I...

Страница 4: ...bers 24 Approved Antenna List 25 FCC IC Requirements for Modular Approval 25 OEM Equipment Labeling Requirements 26 Antenna Requirements 26 Warnings Required in OEM Manuals 26 Channel Warning 26 Appen...

Страница 5: ...y client configured transceivers synchronized to it To establish synchronization between transceivers the server emits a beacon upon detecting a beacon an RF link is established and a GPIO is toggled...

Страница 6: ...4490 1x1 3 Channel Sets AC4490 200 3 Channel Sets AC4490 1000 2 Channel Sets Security One byte System ID 56 bit DES encryption key Interface Buffer Size Input Output 256 bytes each TRANCEIVER Frequenc...

Страница 7: ...C4490 1x1 1 00 x 1 00 x 0 162 CERTIFICATIONS AC4490 200 AC4490 1000 FCC Part 15 247 KQL 4x90200 KQLAC4490 Industry Canada IC 2268C 4x90200 2268C AC44901000 Caution ESD Sensitive Component You must use...

Страница 8: ...e 3 Output Voltage Characteristics Signal Name Module Pin 1x1 Pin Type High Min Low Max Unit GO0 1 19 O 2 5 8 mA 0 4 8 mA V TXD 2 6 O 2 5 2 mA 0 4 2 mA V Hop Frame 6 1 O 2 5 2 mA 0 4 2 mA V CTS 7 9 O...

Страница 9: ...dded Wireless Solutions Support Center http ews support lairdtech com www lairdtech com ramp 9 Copyright 2016 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 292...

Страница 10: ...enabled in EEPROM the OEM Host can take this High when it is not ready to accept data from the transceiver Note Keeping RTS High for too long can cause data loss 9 19 O GO1 Generic Output pin 10 2 PWR...

Страница 11: ...range of a server on same Channel and System ID Always low on a server radio N A 14 RF RF Port RF Interface N A 22 I Reset Active Low version of UP_RESET If RESET is used UP_RESET should be left floa...

Страница 12: ...he operation of CTS CTS On specifies the amount of bytes that must be in the buffer for CTS to be disabled logic High Even while CTS is disabled the OEM host can send data to the transceiver but it sh...

Страница 13: ...rage area 2 Measure the RSSI to obtain the minimum value with no other signal present 3 Power up another transceiver and begin sending data from that transceiver to the transceiver being measured Make...

Страница 14: ...ata rate Refer to the following sections to ensure that the OEM host data rate matches the serial interface baud rate Serial Communications The AC4490 is a TTL device which may connect to a compatible...

Страница 15: ...corresponds to 1 Space S corresponds to 0 Serial Interface Baud Rate This two byte value determines the baud rate used for communicating over the serial interface between the OEM Host and the transcei...

Страница 16: ...Status Receive Acknowledgement Note Implemented in firmware v6 3 and later When enabled in EEPROM GO0 and GO1 perform the functions of Protocol Status and Receive Acknowledgement Protocol Status Every...

Страница 17: ...e OEM asserts its CTS transceivers RTS high the transceiver will wait to send data over the serial bus to the OEM host until the RTS is asserted low CTS should be monitored by the OEM host since this...

Страница 18: ...to be a much wider band than the information they are carrying and they use special pseudo noise codes to make them more noise like It is this characteristic that makes SS signals difficult to detect...

Страница 19: ...logy channel number and system ID are not enough to secure your data the AC4490 supports the Data Encryption Standard DES which is the third level of security Encryption is the process of encoding an...

Страница 20: ...eserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 AC4490 MECHANICAL AND LAYOUT Mechanical Drawings Interface Connector 20 pin OEM Interface connector Molex 87759 0030 mate...

Страница 21: ...dded Wireless Solutions Support Center http ews support lairdtech com www lairdtech com ramp 21 Copyright 2016 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 29...

Страница 22: ...Wireless Solutions Support Center http ews support lairdtech com www lairdtech com ramp 22 Copyright 2016 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0...

Страница 23: ...com ramp 23 Copyright 2016 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 AC4490 TIMING DIAGRAMS Figure 8 Addressed Mode with Timeout Figure 9 Addres...

Страница 24: ...downloadable configuration testing software and integration engineering support COMPLIANCE INFORMATION AC4490 1x1 Due to the RF antenna trace residing on the OEM Host PCB the FCC will not grant modul...

Страница 25: ...Y2283 1 Comtelco Yagi 6dBd X X X Y2283A0915 10RP Comtelco Yagi 6dBd X X X SG101N915 1 Nearson Omni 5 X X X SG101NT 915 Nearson Omni 5 X X X GM113 V Torch Omni 3 5 X X PC8910NRTN Cushcraft Yagi 11dBd...

Страница 26: ...he type size for the text is not required to be larger than eight point 8 pt Antenna Requirements WARNING This device has been tested with an MMCX connector with the above listed antennas When integra...

Страница 27: ...0 and 1x1 leave this to the OEM Some of the most common voltage conversion methods are described below Voltage Level Conversion IC s This is the easiest and most efficient method Laird recommends the...

Страница 28: ...ors to the bottom side ground plane If the input voltage is less than 12 volts C1 and C2 can be replaced with a single 100 F 20 volt capacitor same part number as C7 This will reduce board space and c...

Страница 29: ...ss Solutions Support Center http ews support lairdtech com www lairdtech com ramp 29 Copyright 2016 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 PCB...

Страница 30: ...t Number AC4490 1x1 AC4490 200 AC4490 1000 Size 1 0 x 1 0 x 0 125 1 9 x 1 65 x 0 20 1 9 x 1 65 x 0 20 Range Up to 1 mile Up to 4 miles Up to 20 miles Throughput 32 Kbps 32 Kbps 32 Kbps Current Draw RX...

Страница 31: ...RELATED DOCUMENTS AND FILES The following additional AC4490 technical documents are also available from the RAMP page under the Product Information tab in the row labelled AC4490 900MHz Radio Module...

Страница 32: ...serves the right to make periodic modifications of this product without obligation to notify any person or entity of such revision Copying duplicating selling or otherwise distributing any part of thi...

Отзывы: