Operator's Manual –
Stacker Vendor
©
LAI GAMES
Page 33
Err5 – PRIZE SENSOR BLOCKED or PRIZE SENSOR FAULTY
This error usually occurs if the prize sensor is blocked or a prize is jammed
in the prize chute, blocking the infrared beam of the prize sensor for longer
then 5 seconds. This error can also occur if the sensor output pulses or
“flickers” due to miss alignment for more then 20 times every 5 seconds.
The sensor can be tested using the switch test,
(See
Page 11 for Details)
. If
the sensor is blocked
C7
will be displayed in this test. Clear what ever is
blocking the sensor and the error will clear itself.
If you cannot find anything blocking the sensor, there could be faulty
infrared sensors or receivers on the prize sensor. The sensor PCB’s should
be returned to your nearest LAI Games distributor for repair.
The Prize Sensor is designed around 12 pairs of infrared detectors and
LEDs. Blocking the infrared path of any one of the 12 beams will trigger a
common output. There are 6 orange LEDs on each Sensor PCB to help
indicate the active pairs of infrared beams.
Err6 – All PRIZE ARMS STATUS are DISABLED.
This error will only be displayed if programmable adjustments
P17
to
P22
(Minor Prize Arm Status) and / or adjustments
P23
to
P26
(Major Prize
Arm Status) are all set to
OFF
(Disabled).
There should be at lest one Minor Prize Arm and one Major Prize Arm set
to Status to
ON
. Push the test button once to enter directly to
P17
or
P22
in adjustment mode, locate what prize arms need to be active and set that
Prize Arm Status to
ON,
(See Page 14 for Details)
.
Err7 – MINOR PRIZE DEPLOYMENT ERROR
This error is usually displayed if an empty Minor prize arm is selected by a
Minor prize-winner or if the game activates the Minor prize arm and does
not sense a prize dropping through the prize sensor. The Err4 error code
and the Minor Prize Arm location numbers are displayed alternatively.
The error can also occur if the Minor prize arm
“TIMES OUT”
caused by
taking to long to dispense a Minor prize. This can happen if there is more
than half a prize arm length between Minor prizes on the Minor prize arm,
the Minor prize arm is not turning or the prize sensor is not working.
Test the prize arm function using the Run Test,
(See Page 13 for Details)
.
Test the prize sensor using the Switch Test,
(See Page 11 for Details)
. Pass
your hand through the infrared beams in the prize chute. Blocking the
invisible beams should display
C7
in switch test. Removing your hand
from the beams should stop
C7
from being displayed.
* NOTE! *
P25
setting will affect what the action the game will take on an error 7
[Err7]
.
Please see Program Adjustments on
page 14
for more information.
Содержание Stacker Vendor
Страница 52: ...Operator s Manual Stacker Vendor LAI GAMES Page 47 3D PARTS EXPLODE...
Страница 53: ...Operator s Manual Stacker Vendor LAI GAMES Page 48...
Страница 54: ...Operator s Manual Stacker Vendor LAI GAMES Page 49...
Страница 55: ...Operator s Manual Stacker Vendor LAI GAMES Page 50...
Страница 56: ...Operator s Manual Stacker Vendor LAI GAMES Page 51...
Страница 57: ...Operator s Manual Stacker Vendor LAI GAMES Page 52...
Страница 58: ...Operator s Manual Stacker Vendor LAI GAMES Page 53 Stacker Vendor MAIN WIRING DIAGRAM...
Страница 59: ...Operator s Manual Stacker Vendor LAI GAMES Page 54 Stacker Vendor POWER WIRING DIAGRAM...
Страница 60: ...Operator s Manual Stacker Vendor LAI GAMES Page 55 Stacker Vendor OPTIONAL WIRING DIAGRAM...