(P/N)732.018 Rev N 11/14 • © copyright 2009-2014
Kaba Mas LLC
Page 1 of 3
The ComboGard Pro Lock has three states of operation:
Factory
Default, Manual Setup
, and
Active
. ComboGard Pro locks are
shipped from LA GARD in Factory Default state without Users or
features enabled. Refer to the
ComboGard Pro Setup Instructions
(731.018)
if Lock settings have not already been programmed.
Factory Default:
The Lock must be in the Factory Default state to
be programmed by the PC software.
Factory mode functions as follows:
•
1
key – When pressed, will open the Lock.
•
0
key – When pressed, prompts the ComboGard Pro Setup
software to send the configuration settings to the Lock.
OR
if pressed and held, places the Lock into Manual Setup.
• All other keys perform no function.
Manual Setup:
The Lock can be configured using the keypad only.
Active:
To activate the Lock and freeze the configuration, the
Manager combination MUST be changed.
PROGRAMMABLE LOCK FEATURES
MODES
(Multiple Modes may be selected.)
•
Silent Alarm
(Alarm Box Required - P/N 2789NC)
If enabled, this option will send a signal to an outside alarm
system through the LA GARD Alarm Box.
• Dual Mode
If enabled, two combinations will be required to operate the Lock.
The Manager and one additional User must be active.
• Time Delay Override
If enabled, User 9 can override delay period.
User 9 must be active.
EXTERNAL SIGNALS
(Alarm Box Required - P/N 2789NC. Only
one External Signal type may be selected.)
An external input signal to the Alarm Box will either disable the Lock
from opening, override the time delay, or enable the remote override
depending on the selection programmed for External Signals.
• External Signal disables Lock opening with valid combination.
•
OR
External Signal overrides Time Delay. (This option is ONLY
available if enabled using Setup software.)
•
OR
External Signal enables the Remote Override. (This option
is ONLY available if enabled using Setup software,
and with
Lock code level 39E v1.09 or higher.
)
TIME DELAY
• Delay Period 1 - 99 minutes
• Open Period 1 - 19 minutes
MANAGER INSTRUCTIONS
COMBOGARD
PRO
39E Electronic Combination Locks
COMBINATION LENGTH
A combination length from six (6) to nine (9) digits may be selected.
NOTE:
To maintain the VdS Class 2 and EN 1300 Class B
certification when the duress alarm feature is used, a combination
length of 7 digits or longer must be selected.
LOCK USERS
Super Master Reset - Resets Lock to Factory State
Manager
• Open Lock
• Change Combination
• Enable/Disable Users
• Delete Users
• Set Time Delay Values
• Audit Lock
Up to 9 Users
• Open Lock
• Change Combination
STANDARD LOCK FEATURES
Wrong Try Penalty
• Entry of four (4) consecutive invalid combinations initiates a five
(5) minute delay penalty.
Lock responses during the penalty period are as follows:
- The LED will flash every ten (10) seconds.
- If any key is pressed, the Lock will flash the LED and beep
three times.
• Once the penalty period has ended, two (2) consecutive invalid
combinations will initiate another five (5) minute penalty period.
Low Battery Warning
• Repeated audio/visual signals (LED flashes/beeps) during Lock
opening indicate the battery is low and should be
replaced immediately.
• If the battery level becomes too low to safely operate the Lock,
pressing any key will initiate the low battery warning.
The battery must be replaced before the Lock will operate.
Audit Records
• Lock records the last 63 events in non-volatile memory.
• Audit file cannot be deleted from the Lock.
• Only the Manager can audit the Lock.
• ComboGard Pro auditing software and an Interface Adapter are
required to retrieve a Lock audit.
Dual-Handed
Swing Bolt
Dead Bolt
3750-K
Round Entry
3125
Round Entry
LOCKS
ENTRY DEVICE OPTIONS
8130
(Optional)
3190 Privat
II
(Optional)