oPENING THE LoCK

 (With eKEY or eKEY

II

)

1. Enter valid combination and insert and remove key.
2. The unit will indicate a valid combination and key entry with a double signal.
3. Within four (4) seconds, turn the keypad to the open position (clock-wise) if using a dead bolt style lock, or turn the handle to the open
  position if using a swing bolt style lock.
4. Pull door open.
• 

Invalid Combination Entry

 - Unit will signal three (3) times.

LOCKS USING THE KEY FEATURE MUST BE ORDERED THAT WAY FROM THE FACTORY.  PLEASE SEE PRICE LIST FOR PART 
NUMBERS FOR LOCKS SET-UP FOR eKEY or eKEY

II

 USE.

CHANGING YoUR CoMbINATIoN

 (With eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

If your unit is programmed for Dual Combination, each combination must be changed independently.
1. Enter existing combination and 

hold in key until unit double signals and the LED stays on.

2. Remove key.
3. Press the “0” key.
4. Enter your 

NEW combination two times, inserting and removing the user’s key after each complete combination entry.

  Lock will signal twice after each combination entry and key insert.
5. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

6. Test unit operation several times before closing the door.
• 

Valid Combination Entry

 - Double signal after valid combination is entered.

• 

Invalid Combination Entry

 - Triple signal indicates the old combination is still valid.

MANAGER CoMbINATIoN MUST bE CHANGED PRIoR To PERFoRMING ANY ACTIoN oTHER THAN oPENING THE LoCK

ACTIVATING USER

 (Manager Only, with eKEY or eKEY

II

)

ALWAYS PERFoRM THIS oPERATIoN WITH THE DooR oPEN
1. Enter Manager combination and 

hold in key until unit double signals and the LED stays on.

 

2. Remove key.
3. 

PRESS 1.

 Unit signals twice.

4. Press User number, 2 to 9. Unit signals twice.
5. Enter 

NEW User combination two times, inserting and removing the user’s key after each complete combination entry.

  Lock will signal twice after each combination entry and key insert.
6. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

• 

Valid Combination Entry

 - Double signal after valid combination is entered.

• 

Invalid Combination Entry

 - Triple signal indicates the old combination is still valid. 

DISAbLE USER 

(Manager Only, with eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter Manager combination and 

hold in key until unit double signals and the LED stays on.

2. Remove key.
3. 

PRESS 2.

 Unit signals twice.

4. Press User number, 2 to 9. Unit signals once.
5. User is temporarily disabled. (User combination is saved and will be valid if reinstated.)
6. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

REINSTATE USER 

(Manager Only, with eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter Manager combination and 

hold in key until unit double signals and the LED stays on.

 

2. Remove key.
3. 

PRESS 1.

 Unit signals twice.   

4. Press User number, 2 to 9. Unit signals once.
5. User is reinstated.
6. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

DELETE USER 

(Manager Only, with eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter Manager combination and 

hold in key until unit double signals and the LED stays on.

 

2. Remove key.
3. 

PRESS 3.

 Unit signals twice.

4. Press User number, 2 to 9. Unit signals once.
5. User and combination are removed from the lock. (Add user feature is still available.)
6. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

© copyright 2006-2008 

 

(P/N)759.128 Rev A • 12/08 

Kaba Mas LLC

page 3 of 4