![LaGrand AUDITGARD Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/lagrand/auditgard/auditgard_programming-instruction_3298221002.webp)
REINSTATE USER
(Manager Only, without eKEY or eKEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager combination and
hold down last digit of combination until unit double signals and the LED stays on.
2.
PRESS 1.
Unit signals twice.
3. Press User number, 2 to 9. Unit signals once.
4. User is reinstated.
5. If a mistake is made wait thirty (30) seconds and repeat steps
1 - 3
.
DELETE USER
(Manager Only, without eKEY or eKEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager combination and
hold down last digit of combination until unit double signals and the LED stays on.
2. PRESS 3. Unit signals twice.
3. Press User number, 2 to 9. Unit signals once.
4. User is deleted.
5. If a mistake is made wait thirty (30) seconds and repeat steps
1 - 3
.
CHECK USER STATUS
(Manager Only, without eKEY or eKEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager combination and
hold down last digit of combination until unit double signals and the LED stays on.
2.
PRESS AND HOLD DOWN 1.
Unit signals twice.
3. Press User number, 2 to 9.
4. Unit will signal once if the user is active, twice if the user is disabled, three times if the User is available. The unit will signal with one
extended signal is the User is unavailable.
5. To exit
PRESS 0 or 1.
SET/CHANGE TIME DELAY VALUES
(Manager Only, without eKEY or eKEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager combination and
hold down last digit of combination until unit double signals and the LED stays on.
2.
PRESS 9.
Unit signals twice.
3. Enter Delay period value, from 00 to 99 minutes. For example five (5) minutes would be entered by pressing the 0 key and then the 5 key.
4. Enter Open period value, from 00 to 19 minutes. For example two (2) minutes would be entered by pressing the 0 key and then the 2 key.
Unit will signal twice.
NOtE: Selecting 0000 minutes deactivates the time Delay Feature.
5. Reenter to confirm values. Unit signals twice and feature is active.
NOtE: If time Delay is active it may only be deactivated or delay value decreased in Open Period.
RECEIVE AUDIT
(Manager Only, without eKEY or eKEY
II
)
this function requires Serial Interface (P/N 43087) and LGVIEW Software
1. Plug Interface into PC and open LGVIEW software on PC.
2. Connect Interface to front of keypad and click safe icon button on the PC software to begin acquisition.
3. Enter Manager combination and
hold down last digit of combination until unit double signals and the LED stays on.
4.
PRESS 7.
Unit signals once and Audit will be sent.
5. Disconnect Interface Cable from PC and keypad.
DUAL MoDE
(If feature is active, without eKEY or eKEY
II
)
1. Must add at least one (1) user to open lock. (See
ADD USER)
• At least one user must be active; all users cannot be disabled or deleted.
2. If Time Delay is active, one valid combination will start Delay period.
• Two combinations required to open lock in Open period.
NOtE: In Dual Mode a valid user combination must be entered before the Manager Combination in order to use Manager Functions 1, 2, 3, 7 and 9.
TIME DELAY oVERRIDE
(If feature is active, without eKEY or eKEY
II
)
• Must add User 9. (See
ADD USER)
- If User 9 is disabled or deleted, this feature will no longer function.
• Entry of Override combination during Delay period will open the lock.
NOTE: If Time Delay is enabled, User 9 can only be added during the Open period.
SILENT SIGNAL ALARM
(If feature is active AND optional Alarm Box is connected to an alarm system.)
• Enter last digit of combination one number higher or one number lower.
Example:
Combination:
1-2-3-4-5-6
Duress: 1-2-3-4-5-5
or
1-2-3-4-5-7
• The lock will open without any indication that the duress signal has been sent.
DISAbLE LoCK
(If feature is active AND optional Alarm Box is connected to an alarm system.)
• Alarm Box (2789 or 4002) required.
Input signal to the Alarm Box will either disable the lock opening or disable all lock functions., depending on mode programmed with LG-Audit
Setup Software.
© copyright 2006-2008
(P/N)759.128 Rev A • 12/08
Kaba Mas LLC
page 2 of 4