background image

STANDARD FEATURES 

ACTIVE

MANAGER CoMbINATIoN

 (Factory set to 1-2-3-4-5-6 or 7-8-9 

depending on combination length)

WRoNG TRY PENALTY
•  Four (4) consecutive invalid combinations initiates five (5) minute
  delay period.
LoW bATTERY WARNING
•  Repeated LED flashing and repeated beeping during opening
  indicates battery is low and needs immediate replacement.
AUDIo AND VISUAL SIGNAL
•  Double signal - two (2) LED flashes and two (2) beeps - indicates
  entry is valid or accepted.  
•  Triple signal - three (3) LED flashes and three (3) beeps - indicates
  invalid or not accepted.
AUDIT TRAIL
512 Audits with User ID, timestamp and operation
•  For audit features see LG-AUDIT Software Package

CoMbINATIoN LENGTH 

 

 

•  Activate/Delete Users
•  Enable/Disable Users
•  Set Time Delay Values
•  Open Lock
USER CoMbINATIoN
•  Open Lock
•  Change Combination
TIME DELAY
•  Delay period 1 - 99 minutes 

 

 

•  Open period 1 - 19 minutes 

 

 

DUAL MoDE

 

 

 

£

•  Two combinations required to open

SIGNAL To DISAbLE LoCK oPENING

 (Alarm Box Required)

•  Input signal disables opening of lock by valid combination

PC PRoGRAMMAbLE FEATURES
MULTIPLE USERS 

(Up to nine

 - 

1 Manager and 8 Users)

User # Installed 

9

     

£ £ ££ £ £ £ £

TIME DELAY oVERRIDE

 

£

•  Ability to add second combination to override delay period
SILENT SIGNAL ALARM

 (Alarm Box Required) 

£

•  Duress signal if last number of combination(s) is entered using
  one number higher or one number lower.
SIGNAL To DISAbLE LoCK

 (Alarm Box Required) 

•  Input signal disables opening with valid combination OR 

£

•  Input signal disables all lock functions. 

£

AUDITGARD

66E Firmware
4300 Dual-Handed Swingbolt
6040-DB Deadbolt Lock Instructions

MANAGER PROGRAMMING

© copyright 2006-2008 

 

(P/N)759.128 Rev A • 12/08 

Kaba Mas LLC

 

page 1 of 4

•  All locks are shipped from the factory in Pre Set-up mode, with
  no features installed.  
•  Lock will open when 1 is pressed.  
•  Please follow LG-AUDIT PC software instructions to initially
  configure locks to default settings.

MANAGER CoMbINATIoN MUST bE CHANGED PRIoR To 
PERFoRMING ANY ACTIoN oTHER THAN oPENING THE LoCK
oPENING THE LoCK

 (Without eKEY or eKEY

II

)

1. Enter valid combination.
2. The unit will indicate a valid combination entry with a double signal.
3. Within four (4) seconds, turn the keypad to the open position
  (clock-wise) if using a dead bolt style lock, or turn the handle to the
  open position if using a swing bolt style lock.
4. Pull door open.
•  Invalid Combination Entry - Unit will signal three (3) times.

CHANGING YoUR CoMbINATIoN

 (Without eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

If your unit is programmed for Dual Combination, each combination 
must be changed independently.

1. Enter existing combination and 

hold down the last digit until unit

  double signals and the LED stays on.

2. Press the “0” key.
3. Enter your NEW combination two times.
4. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

Note:

 Test unit operation several times before closing the door.

CAUTION: When selecting a combination do not use 
birthday or other predictable data that could give 
correlation between the user and combination. Keep the 
combination secret.

• 

Valid Combination Entry

 - Double signal after valid combination

  is entered.
• 

Invalid Combination Entry

 - Triple signal indicates the old

  combination is still valid.

ACTIVATING USER

 (Manager Only, without eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter Manager combination and 

hold down last digit of

  combination until unit double signals and the LED stays on.

 

2. 

PRESS 1.

 Unit signals twice.

3. Press User number, 2 to 9.Unit signals twice.
4. Enter 

NEW User combination two times.

5. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

• 

Valid Combination Entry

 - Double signal after valid combination

  is entered.
• 

Invalid Combination Entry

 - Triple signal indicates the old

  combination is still valid. 

DISAbLE USER

 (Manager Only, without eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter Manager combination and 

hold down last digit of

  combination until unit double signals and the LED stays on.

2. 

PRESS 2.

 Unit signals twice.

3. Press User number, 2 to 9. Unit signals once.
4. User is temporarily disabled. (User combination is saved and will
  be valid if reinstated.)
5. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

4300

Dual-Handed

Swingbolt

6040-DB
Deadbolt

3750-K

Round Entry

3125

Round Entry

LOCKS

SUGGESTED KEYPADS