UNICO 01.07.2019
English / Englisch
7
MAINTENANCE WORK AND REPLACEMENT OF WEARING PARTS
7.6 REPLACING THE FLUORESCENT LAMP
Whenever the fluorescent lamp is defective, it must be replaced.
Use only original LÄGLER
®
fluorescent lamps (
part number in
Section 11, Spare parts UNICO
)!
Let the light cool off before you proceed as follows:
1
Switch off the machine and pull the power plug out of the
socket!
2
Swivel the working light upward (fig. 82).
CAUTION!
RISK OF INJURY by broken pieces of glass:
Do not break the protective tube and the fluorescent lamp!
You could become injured by broken pieces of glass or you
could also damage the floor!
3
On the plastic fixture housing of the working light, press the
two clips together that hold the protective tube and then
remove the fluorescent lamp carefully (fig. 83).
4
Wrap a cloth or similar item around the fluorescent lamp and
then pull the fluorescent lamp off the fixture. If appropriate,
move the fluorescent lamp back and forth carefully (fig. 84).
5
Insert a new fluorescent lamp. You must feel the fluorescent
lamp snap into place.
6
Insert the protective tube again. Make sure the two clips
snap into place properly. Adjust the working light according
to your requirements (
Section 4.10, Adjusting the working
light
).
Fig. 84
Pull the defective fluorescent lamp out of the
fixture
carefully
.
Fig. 83
Press the two clips on the fixture housing together
and then remove the protective tube
carefully
.
Fig. 82
Swivel the working light upward.
49