Problem

Possible Cause / Solution

Startup

Maintenance

A) Foamer sputtering or foam not acceptable
B) Foam is too wet
C) No foam output / unit will not foam
D) Tank will not pressurize and/or hold pressure

1, 2
1, 2
1

3, 4

3, 4
3

Possible Cause / Solution

Startup

Maintenance

1.  Not enough air pressure

Pump up the foamer several strokes
Less liquid in the tank will allow for more air pressure to
build and foam for longer without re-pumping (use a half
full tank for best results)
The air relief valve will rise when maximum pressure is
achieved

2.  Solution too weak

Increase concentration of chemical solution
Ensure that the chemical foams naturally or use a
foaming additive (not all chemicals foam)

3.  Air leaks due to loose lid, worn or damaged

components/fittings

Ensure lid is snug, but not overtight. Lubricate the lid
and pressure relief o-rings. Order repair kit and replace
damaged o-rings, gaskets, umbrella valve etc. See page
3 for part numbers
Refer to the Pump-Up O-Ring Replacement Guide

http://appequip.net/uploads/documents/pump-up-o-ring-
replacement.pdf

The o-ring on the piston (inside the shaft) creates
pressure and should be kept well-lubricated since it is
exposed to friction from pumping.  Replace as needed.
The umbrella valve on the bottom of the piston shaft
holds pressure in the tank and needs to form a tight
seal.  Do not scratch the valve seat!  Replace as
needed.
Ensure that your chemical and lubricant are compatible
with the o-ring seals for this equipment.  Incompatible
chemicals or lubricants can quickly degrade the o-rings.

4.  Debris clogging foamer body

Relieve air pressure by gently pulling up on pressure
relief valve stem and remove the lid. Reach inside and
pull down on the chemical tube to remove it along with
the (grey) foamer body, visually inspect and remove
debris from the small ports in the foamer body. Replace
foamer body and tube.

5.  Foam pads clogged

Remove foam pads from gun (see diagram) and rinse to
remove debris and/or chemical buildup before
replacing.  Replace as needed.

PREVENTIVE MAINTENANCE: * Prior to storage, empty, clean and dry the foamer. * Lubricate o-ring in pressure relief valve and the piston/cylinder
with a compatible non-water soluble grease (such as a silicone lubricant) on a regular basis. * Lubricate tank cap threads and both sides of the gasket
to achieve a tight seal and to ease tightening and loosening. * Replace cracked or damaged seals before use.