Lafferty 910310 Скачать руководство пользователя страница 4

Troubleshooting Guide

Problem

Possible Cause / Solution

Startup

Maintenance

A) Foam surges or sputters.
B) Foam too dry.
C) Foam too wet.
D) Solution drips after shutting down.

1, 2, 3, 4, 5
1
1, 3, 4, 5

6, 7, 8

6
6

Possible Cause / Solution

Startup

Maintenance

1.  Air volume too high or too low

Adjust the needle valve very slightly counterclockwise
for dryer and clockwise for wetter. VERY little air is
needed, if the top hole is sputtering you have too much
air on them, turn needle valve knob slightly clockwise
until all holes produce foam.

2.  Use of an oiler in the airline will cause poor foam quality

Use only clean, dry air.

3.  Solution Pressure too Low

Must be 40 PSI minimum. 60 PSI maximum

4.  Not enough chemical. 

Increase concentration.

5.  Discharge tubes kinked or wrong size.

Straighten the tubes or replace with correct size.

6.  Solution Chemical check valve stuck or failed.

Clean or replace.

7.  Leak in air or solution connections. 

Tighten the connection or cut off 1/2" of tube and
reconnect.

8.  Needle valve clogged not allowing enough air

Clean or replace.​​​​​​​

9.  Chemical build-up may have formed in the foamer causing

low flow

When there is no flow at all, carefully remove fittings
and soak entire foam wand  in descaling solution. Or
replace.

PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush the chemical out
of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical strainer and replace if missing.

910310 • Triple Foam Stick Set