Lafayette 54035A Скачать руководство пользователя страница 7

Model 54035A      User’s Manual

Fax: (765) 423-4111  .  www.lafayetteinstrument.com  .  [email protected]

7

Optional Accessories

The 54035A currently has two accessory items that may be useful in some applications

Banana Plug Interface: 

 Provides a way to connect standard banana plugs to the external input terminal blocks.

Timer Control Software:

 

 Provides a software program to control the timing and counting functions of the timer 

via the computer. Also provides data storage capability so that timing data can be stored in a file and analyzed 

at a later date.

Contact Lafayette Instrument about pricing and availability of these products.

Communications

The 54035A provides a communications port so that it can be connected through a computer via a standard 

serial port. The main purpose of this function is  to provide a way to get the data collected by the timer into the 

computer for storage and analysis. An effort was made to keep the communication protocol and commands 

simple enough so that the user could easily write their own timer control application. In the event that resources 

are unavailable for writing applications, a ready made software program is available from Lafayette Instrument. 

The serial port on the computer should be set as shown below:

Serial communication protocol: 4800 baud, no parity, 8 bit ASCII, 1 stop bit or  (4800,N,8,1).

The 54035A sends and receives only ASCII characters. Each control is activated by sending a single ASCII 

character ( the timer is case sensitive):

 

 

 

 

 

ASCII

 

   

Function

 

 

 

   S 

-  Start

    

 

 

   1 

-  Stop1

 

 

 

   2 

-  Stop2

 

 

 

   3 

-  Stop3

  

 

 

   4 

-  Stop4

 

 

 

   C 

-  Begin run/count

 

 

 

   E 

-  End run/count

 

 

 

   M 

-  Mode

 

 

 

   R 

-  Reset

 

 

 

   D 

-  Upload data

When the “Upload Data” command is issued, the timer will respond by sending all time and count data (even 

if it is zero).  The data is sent as seven ASCII bytes per data value in this order: Count1, Time1, Time2, Time3, 

Time4, Count2, Count3. The serial buffer, therefore, should be set up to receive 49 bytes with the length set to 

7. Once the data is received, it can be broken up into its seven character data sets.

If the mode menu is accessed via the serial port, the computer will need to send, in succession, the same 

ASCII value as the number requested on the timer display (if the choice is “1-single 2-multiple” send a “1” or a 

“2” and so on).

The data sent to computer is the same as displayed on the timer. For example, if stop1 is pressed on the front 

panel, that data will be placed in time1 on the serial communication. In multiple timer mode, the master time 

data will be placed in time1 no matter which stop is pressed. Likewise, the count data will be placed in count1, 

the data for run1 will be placed in time2 and count 2, and the data for run2 will be placed in time3 and count3. 

There will be no count2 or count3 data available in single timer mode. Also, run1 and run2 are not accessible 

through the computer, only through the back panel. However, the data for these inputs can be uploaded to 

the computer. 

Содержание 54035A

Страница 1: ...t com Model 54035A Multifunction Timer Counter User s Manual 3700 Sagamore Parkway North Lafayette IN 47904 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 info lafayetteinstrument com www lafayett...

Страница 2: ...ion Timer Counter Model 54035A is designed to time and count events with high accuracy and high resolution It features millisecond timing up to 1000 seconds and counting up to 1000 counts It can take...

Страница 3: ...mode button on the front panel or via instructions on the serial communication port seeCommunications directions pg 9 for details In order to enter the mode menu the timer must be reset Single Mode T...

Страница 4: ...ation To prevent accidental loss of data the timer must be reset before the mode menu can be entered If single timer operation is selected the timer will give a prompt for the desired number of split...

Страница 5: ...external input is the only way to activate run1 count1 3 Stop2 Run2 In single timer mode this input is for stop2 in multiple timer mode it is for run count2 This external input is the only way to act...

Страница 6: ...ries is provided on the bottom of the 54035A Using a screwdriver or coin turn each of the thumbscrews and remove the battery cover plate The batteries are provided with two ribbon loops to aid in remo...

Страница 7: ...sends and receives only ASCII characters Each control is activated by sending a single ASCII character the timer is case sensitive ASCII Function S Start 1 Stop1 2 Stop2 3 Stop3 4 Stop4 C Begin run c...

Страница 8: ...1 Selecting the comm port in use by the mouse will result in an error and or disabling of the mouse If the mouse is disabled the computer will have to be restarted to restore function Timing function...

Страница 9: ...g results start and stop the timer from the front or back panel on the 54035A and use the computer to upload the time data Results File Format All time and count data is stored in an ASCII format Any...

Страница 10: ...D input on the timer The54035Awilldisplaythetimeontargetonthemaintimer timeofftargetontimer1andtherevolutioncount on timer 2 press scroll in multiple timer mode to view timer 2 data If the rotary purs...

Страница 11: ...binding posts on the Stability Platform to an input and ground on the 54035A 2 Connect the center binding post to the RUN CNT input 3 Connect the right binding post to RUN1 input 4 Connect the left bi...

Страница 12: ...nding posts on the Stability Platform to an input and ground on the 54035A 2 Connect the center binding post to the RUN CNT input 3 Connect the right binding post to RUN1 input 4 Connect the left bind...

Страница 13: ...rom the maze to the START input on the Multifunction Timer Counter 3 Connect the stop jack from the maze to STOP3 on the timer 4 Connect the error jack on the maze to RUN1 on the timer 5 Connect the s...

Страница 14: ...t of each switch to the one of the four GND inputs on the rear of the 54035A To start an event a remote pushbutton can be connected to the START input on the rear of the 54035A or a trial can begin by...

Страница 15: ...ing post on the board connects to any GND input on the 54035A The stylus for the tapping board connects to the RUN CNT input The 54035A will show the number of counts or taps along with the contact ti...

Страница 16: ...ranty repairs Damaged Goods Damaged instrumentation should not be returned to Lafayette Instrument prior to a thorough inspection If a shipment arrives damaged note damage on delivery bill and have th...

Отзывы: