30
Laetus web technology | 13 9 66 0802 | FirmwareVersion 1.1.x/2.0.x | 2009-10
Setup – Product Format Parameters
Fig. 24 Example - Tube with a bar
Table 1: Setting the follow-up control
The GOOD signal begins 6 mm behind the last code bar. In the case of the
orientation modes
by Time
and
by Length
, the motor of the turning station is
stopped when the time in ms, the distance in mm or the number of bars specified
under "Orientation Parameter" is reached.
For this, please read the "Installation Instructions COSI 221".
Make the appropriate selection and confirm by pressing
OK
or discard any changes
made by pressing
Cancel
.
If you press the
Save
button, the changes will be stored and also be applied in future.
Tube Orientation Signal
Orientation Parameter
Deactivated
---
by Length
6–310 mm
by Bars
1–16
by Time
10–500 ms