Laetus web technology | 13 9 66 0802 | FirmwareVersion 1.1.x/2.0.x | 2009-10
Setup – Product Format Parameters
4.3.3 Result Pulse Output – Immediately / End of Gate
In most applications, the GOOD signal is transmitted for processing at the end of the
reading. In tube filling machines, the result output is expected immediately after
coding. In this case, the GOOD signal appears immediately after the clearance
distance behind the code.
If you press the "
...
" (Fig. 18) button, a window is called up in which you can choose
between:
Immediately
End of gate
Fig. 21 Result output mode
Make the appropriate selection and confirm by pressing
OK
, or close the selection
menu without making any changes by pressing
Cancel
.
If you press the
Save
button, the changes will be stored and also be applied in future.