Replacing Chest Rise Bladder
If the Chest Rise Bladders leak or are damaged:
1 Open the Torso Skin to expose the Chest
Plate. There is one bladder on each side of the
Chest Plate assembly.
2 Disconnect the tube from the bladder.
3 Discard the used bladder.
4 Insert new bladder.
5 Reconnect the tube to the new bladder.
Left Leg to Pelvis – Tube Descriptions
Name/Label
Tube Color
Connector Description
Pneum L
Silicon
Barb connector
Pneum R
Silicon
Barb connector
Chest L
Silicon
Barb connector
Chest R
Silicon
Barb connector
Replacing Lung Bladders
If leaking occurs, the lung bladders (in the chest cavity) should be
replaced.
1 Open the Torso Skin and put the Stomach Foam to the side.
2 Open the hinged chest plate upwards, to access the lungs.
3 Remove the chest compression spring for easier access to the
lungs.
4 Unhook the yellow lung compliance bands from each side of the
lung assembly.