3 Detach the Simulation Tubes
The Simulation Tubes are attached to the right side
of
NeoNatalie’s
chest. Pull gently on the Tubes to
release them.
Tip: After delivering NeoNatalie, reattach the Simulation
Tubes to simulate spontaneous breathing and palpable
umbilical pulse.
4 Attach the Umbilical Cord
Connect the Umbilical Cord from the Placenta
to
NeoNatalie
by clicking the two connectors
together.
Tip: To detach the cord, break the connection
point with your thumbs as shown in the
illustration above.
To Prepare MamaNatalie
li
li
li
li
1 Inflate the Uterus Air Reservoirs
The Uterus contains two reservoirs. Air can be
manipulated from one reservoir to another to
simulate various uterus conditions.
a) Open the Air Valve.
b) Use the
NeoNatalie Suction
to inflate the
Uterus Reservoirs with air. Adjust the amount
of air until you pass the test for correct inflation
level (as described on the next page).
c) Close the Air Valve.