MamaNatalie

Birthing Simulator

Directions for Use

www.laerdalglobalhealth.com

Содержание MamaNatalie

Страница 1: ...MamaNatalie Birthing Simulator Directions for Use www laerdalglobalhealth com...

Страница 2: ...adder 8 4 Position the Squeaker Unit 8 5 Optional Protection against fluid spillage 8 6 Attach MamaNatalie onto your body 8 7 Hang the Uterus over the hook 8 8 Optional For Cervix Landmark 9 To operat...

Страница 3: ...irs of Gloves 1 normal and 1 long 5 Fetal Stethoscope 6 Fluid Collection Tray 7 Floor protector 8 Fluid Drain 9 Urine Catheter 10 20 ml Syringe 11 NeoNatalie Skull w fontanelles 12 Cervix Ribbon 13 Ba...

Страница 4: ...newborn simulator that facilitates effective learning of essential newborn care including basic resuscitation measures NeoNatalie has realistic size and appearance and also natural weight feel and tou...

Страница 5: ...a funnel Return filling cap c Open the valve Fill NeoNatalie Suction or another suitable irrigation device with water and use this to insert additional water into NeoNatalie s body until the body fee...

Страница 6: ...clicking the two connectors together Tip To detach the cord break the connection point with your thumbs as shown in the illustration above To Prepare MamaNatalie l i l i l i l i 1 Inflate the Uterus...

Страница 7: ...rs A and B Reservoir B should now feel like a soft uterus 2 Fill the Blood Tank i t e r l i t e l a Check that the Blood Valve of the Blood Tank is closed b Ensure that the blood tube is connected to...

Страница 8: ...Fluid Drain to the backside of the Skeleton b Place the Floor protector under the Collection Tray Ensure that the end of the Fluid Drain is inside the Collection Tray Tip Collect the blood in the Col...

Страница 9: ...e buckle Tip Remove the Cervix Ribbon when cervix landmark is not needed during simulation training To operate MamaNatalie 1 Preparing for simulating birth a Fold the Stomach Skin down Open the Uterus...

Страница 10: ...n NeoNatalie s chin Deliver the rest of NeoNatalie by pushing onto the body For easier delivery lubricate NeoNatalie s head with a few drops of water or baby oil before putting NeoNatalie into the Ute...

Страница 11: ...a Do not detach the Placenta If the learner is pulling the cord hold onto the Placenta with your hands to ensure it stays in place 5 Controlling blood flow i t e r l i t e l When starting with the Blo...

Страница 12: ...imulate uterus contraction While moving the position of your hand forwards and below the navel gradually squeeze reservoir A to simulate a uterus contracting and getting harder Squeezing reservoir A f...

Страница 13: ...amaNatalie has a Rectum where medications can be inserted To simulate intramuscular administration of medications use the 20 ml Syringe do not use a needle Tips for performing simulations Pay attentio...

Страница 14: ...light Do not leave MamaNatalie wet inside a bag Clean it and dry it after use Disassembly and reassembly It may be practical to disassemble MamaNatalie before cleaning or other maintenance In order to...

Страница 15: ...he Blood Tube seems to be blocked a Fill the Penguin with water and try to flush the water through the tube from the blood outlet inside the uterus b Inspect the tube from the Blood Tank If the tube i...

Страница 16: ...cal in China Contact address Tanke Svilandsgate 30 P O Box 377 4002 Stavanger Norway Tel 47 51 51 17 00 Fax 47 51 52 35 57 E mail mamanatalie laerdal no MamaNatalie the Laerdal Logo and helping save l...

Отзывы: