background image

LADEmini

Installation

Download full manual

lade.de/lademini-manual-en

Содержание mini

Страница 1: ...LADEmini Installation Download full manual lade de lademini manual en...

Страница 2: ...J45 socket and ribbon cable or Adapter board with IDC connector and ribbon cable D 2 x Screw for adapter board E 1 x Cable gland 7 12 1 x Cable gland 9 17 LADEmini Wallbox F 1 x Cable gland with bend...

Страница 3: ...ng installation cable between IO module and adapter board K 1x LADEgenius L 12 x 2 pole connector M 1 x 3 pole connector N 1 x 4 pole connector O 1 x 4 pole connector large P 1 x 24 V top hat rail pow...

Страница 4: ...ear the house connection Controls up to 96 charging points and other consumers Measures the current at the house connection LADEgenius RT Connects to the cloud via LAN or LTE antenna Numerous other in...

Страница 5: ...ith charging cable display and LED ring LADEmini Cabinet Example for 4 charging points Contains power electronics for one to four charging points pre wired IO Module MID meter RCD type B Contactor 2 x...

Страница 6: ...ply line Data line Pre wired Fuse Main fuse house connection 24 V voltage supply RJ45 socket Ethernet Internet access via LTE router switch LTE antenna Current and voltage measurement Controls up to 1...

Страница 7: ...Schematic representation Contains only components to which cables must be connected Contactor 1 Circuit breaker 1 If no circuit breaker is installed RCD switch Contactor 2 Circuit breaker 2 If no cir...

Страница 8: ...DEgenius to router or switch via Ethernet alternatively install LTE antenna Connect power supply 1 Installing LADEgenius Main fuse house connection The currrent transformer must be mounted so the arro...

Страница 9: ...N N max 16 A Up to 16 IO Modules charg ing points in series distrib uted over several cabinets...

Страница 10: ...s for optimised PV charging Which version is used must be set at the IO Module Meter connected in the cabinet By default an MID meter is installed in the cabinet and connected to the IO Module This is...

Страница 11: ...0 0 0 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 0 1 1 1 8 1 0 0 0 9 1 0 0 1 10 1 0 1 0 11 1 0 1 1 12 1 1 0 0 13 1 1 0 1 14 1 1 1 0 15 1 1 1 1 Which contactor in the cabinet 2 x 2 p...

Страница 12: ...contactor In Italy and the Netherlands installers are obliged to install an additional contactor In this case the corresponding DIP switch must be switched on In Germany this is not necessary Termina...

Страница 13: ...N No OFF default Terminating resistor On ON Off OFF Picture rotated by 180 6 Connect the supply line to the first circtuit breaker from the left on the input side If no circuit breaker has been instal...

Страница 14: ...depending on whether a Cat 7 installation cable is used for the data line between IO Module and charger standard or a pre assembled patch cable The adapter board can be installed in all four corners o...

Страница 15: ...ago clamps L1 L1 L2 L2 L3 L3 N N 8 Connect the earth wires of the supply line the charging cable and the earth bolt using the 3 wire Wago clamp 9 Put on the cover C3 and feed the ribbon cable through...

Страница 16: ...LADE GmbH Wilhelm Maybach Stra e 11 55129 Mainz Germany partner lade de 49 6131 92 66 330 lade de...

Отзывы: