background image

 

 

BASIC BREAKDOWNS 

21 

 

 

6.  

 

BASIC BREAKDOWNS  

 

Figure No.24 -

 

Nickel 700-800-1000 Basic breakdowns 

Nº 

CÓDIGO 

DENOMINACION 

CANTIDAD 

5044700000 

Nickel DC Maneta registro entrada aire 

5044700001 

Nickel DC Cenicero doble 

5044700008 

Nickel 700 DC Separador 

5044800000 

Nickel 800 DC Separador 

5045300001 

Nickel 1000 DC Separador 

5044700004 

Nickel 700 DC Cristal puerta hogar + junta 

5044800001 

Nickel 800 DC Cristal puerta hogar + junta 

5045300000 

Nickel 1000 DC Cristal puerta hogar 

5040000897 

Sylver 800 plus, Parrilla fundición 

5044700002 

Nickel Manilla puerta hogar 

 

Cordón plano pelos 8x2mm 

2,5 m 

509020000042  Cordón Negro Ø13mm 

2,5 m 

5044700009 

Nickel DC Vermiculita Lateral 340x340x60 mm 

10 

5044700010 

Nickel 700 DC Vermiculita Base lateral 210x149x30 mm 

5044800007 

Nickel 800 DC Vermiculita Base lateral 210x199x30 mm 

5045300007 

Nickel 1000 DC, Vermiculita Base Lateral 48x329x30  

13 

5044700007 

Nickel 700 DC Deflector vermiculita  

5044800004 

Nickel 800 DC Deflector vermiculita  

5045300004 

Nickel 1000 DC Deflector vermiculita 

14 

504390000003  Cjto. marco de 25 Silver 700 (For Nickel 700) 

50440000002 

Cjto. marco de 25 Silver 800 (For Nickel 800) 

504410000002  Cjto. marco de 25 Silver 1000 (For Nickel 1000) 

5044800005 

Cjto. marco de 50 Silver 800  (For Nickel 800 South Africa and Australia) 

Содержание Nickel AUSTRALIA

Страница 1: ...Nickel Instruction Book AUSTRALIA ...

Страница 2: ...ng to installers 6 2 2 Room for installation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 8 2 3 3 Checks before lighting for the first time 8 2 3 4 Height adjustment and levelling the appliance 8 2 3 5 Casing 8 2 3 6 Connection to the flue 10 2 3 7 Piping air to the firebox 10 2 3 8 Exterior...

Страница 3: ...ance 18 4 1 3 Flue socket 18 4 1 4 Painted sheet steel cast iron parts 18 4 1 5 Firebox glass 18 4 1 6 Air intake registers 18 4 2 Maintenance of the chimney flue 19 4 3 Important advice 19 TROUBLESHOOTING 20 BASIC BREAKDOWNS 21 CERTIFICATE OF COMPLIANCE 23 ...

Страница 4: ...RALL AVERAGE EFFICIENCY BURNING HARDWOOD 64 60 PARTICULATE EMISSIONS FACTOR g kg 0 9 0 9 HIGH BURN Average power high primary air settings kW 9 9 15 6 Average Peak Power kW 15 8 19 9 Efficiency high primary air settings 57 54 Average dry fuel consumption rate high primary air settings Kg hr 3 2 5 Particulate emission factor oven dry wood high primary air settings g kg 0 8 0 7 MEDIUM BURN Average p...

Страница 5: ... of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warrant To obtain these data tests have been done on the standards AS NZS 4012 2014 AS NZS 4013 2014 and AS NZS 2918 2018 with eucalyptus wood Figure No 1 Dimensions of the Nickel 800 appliance in ...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Nickel 1000 appliance in mm ...

Страница 7: ...f the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated high up in the room at less than 30 cm from the c...

Страница 8: ... wide x 36mm thick floor protector compressed board should be used in front of each of the appliance doors and be placed centrally in the 1110mm width The Thermal resistivity of the 50mm skamol board floor protector is 0 74m K W The Thermal resistivity of the floor protector is 0 16m K W for 36mm thick compressed board sheets Minimum air gap of 40mm must be maintained under the appliance base to t...

Страница 9: ...he deflectors are correctly positioned Make sure that the airtight joints on the flue circuit are in perfect condition Make sure that the doors close properly Make sure that all moving parts are fitted in place 2 3 4 Height adjustment and levelling the appliance The appliance must be perfectly level horizontally and vertically both at the front and on the sides use a spirit level The appliance has...

Страница 10: ...on chosen with or without forced ventilation combustion air from indoors or outdoors directed hot air outlets with or without pipes etc A further hot air ventilation grille is also recommended between the insulating deflector on the hood and the ceiling As well as this the hood closure should have a free opening of at least 100 cm2 for the intake of air for combustion Warning on appliances on whic...

Страница 11: ... bottom front of the appliance If the tube is straight it can have a maximum of 12 meters in length If you use accessories like elbows you must subtract the total length 12 meters 1 meter for each accessory used This is the best option because it means that draughts are not created in and oxygen is not consumed from the room in which the appliance is fitted A further advantage is that there is no ...

Страница 12: ...nd airtight over its entire length The flue must be at least 5m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer from downdraught then it is necessary to fit an effective anti downdraught cowl a static cowl or a smoke extraction fan or reshape the chimney Never make 90º bends due to the great loss of draught they cause and reduce 45º bends down to an a...

Страница 13: ...between chimney crown and roof ridge The chimney crown must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m Figure No 14 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet...

Страница 14: ...stored The logs should have a maximum diameter of 150mm Finely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech hardwood and eucalyptus logs Other fuels Oak chestnut ash maple birch elm etc Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All types of coal and liquid fuel Green wood Green or damp wood ...

Страница 15: ...TIONS OF USE 14 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 17 Operating components on the appliance A Firebox door handle B Air intake o B1 closed left o B2 open right ...

Страница 16: ...ance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Loading fuel In order to load firewood open the firebox door gently preventing the sudden entry of air to the firebox so that smoke does not enter the room that the appliance is inst...

Страница 17: ... operated with all combustion rate controls adjusted to the minimum setting c Medium burn rate The appliance shall be operated with the register in the middle of its position Lacunza recommends doing medium burn cycles 3 6 Removing ash Following sustained use of the appliance it is necessary to remove the ash from the firebox Remove the ashpit box when cold or using something to prevent yourself f...

Страница 18: ...Figure No 20 Remove the refractories from the right side Figure No 21 Turn the right side refractory as in the picture so that the deflector can fall Figure No 22 Drop the refractory holding it Figure No 23 Remove de deflector ...

Страница 19: ...should be kept open However over the hours of use the glass may become dirty To clean it we will use specific degreasing products or dry cleaning products for this task The cleaning should be carried out with the glass cold and taking care not to apply the glass cleaner directly on the glass as if it comes into contact with the door s closing cord it may deteriorate Put the cleaning product on the...

Страница 20: ...ire in the chimney close the flue draught close doors and windows remove embers from the firebox block the connection hole with damp cloths and call the fire brigade 4 3 Important advice Lacunza recommends that only Lacunza authorised replacement parts be used Lacunza accepts no liability for any modification to the product which it has not authorised This appliance is a heat producing appliance a...

Страница 21: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 22: ...nilla puerta hogar 2 7 Cordón plano pelos 8x2mm 2 5 m 8 509020000042 Cordón Negro Ø13mm 2 5 m 9 5044700009 Nickel DC Vermiculita Lateral 340x340x60 mm 2 10 5044700010 Nickel 700 DC Vermiculita Base lateral 210x149x30 mm 4 5044800007 Nickel 800 DC Vermiculita Base lateral 210x199x30 mm 4 5045300007 Nickel 1000 DC Vermiculita Base Lateral 48x329x30 4 13 5044700007 Nickel 700 DC Deflector vermiculita...

Страница 23: ...BASIC BREAKDOWNS 22 6 5045300005 Cjto marco de 50 Silver 1000 For Nickel 1000 South Africa and Australia 2 ...

Страница 24: ...CERTIFICATE OF COMPLIANCE 23 7 CERTIFICATE OF COMPLIANCE ...

Страница 25: ...CERTIFICATE OF COMPLIANCE 24 7 ...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea 5A 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: