PRESENTATION OF THE APPLIANCE
3
1.
PRESENTATION OF THE APPLIANCE
For optimum operation of the appliance, we advise you to read this manual carefully before
switching on the appliance for the first time. In case of problems or concerns, we urge you to
contact your dealer, who will cooperate with you.
In order to improve the product, the manufacturer reserves the right to make changes
without notice by updating this document.
This appliance is designed to burn wood in absolutely safe conditions.
WARNING
: Faulty installation may have serious consequences.
Installation and all necessary regular maintenance operations must be performed by an
authorized installer in full accordance with the specifications set out in the legislation
applicable in each country and this instruction book.
1.1.
General characteristics
Unit
IV-800
Nominal Heat Output (N.H.O.) to atmosphere
kW
8,5
Efficiency at N.H.O.
%
78
CO emission at 13% O2 at N.H.O.
%
0,07
Gas mass flow at N.H.O.
g/s
9,6
Gas temperature of flue at N.H.O.
ºC
238
Gas temperature on the flue socket flange
ºC
286
Optimum flue draught
Pa
12
Wood consumption (beech) at N.H.O.
Kg/h
2,7
Dimensions of the firebox
Width
mm
600
Depth
mm
220
Useful height
mm
295
Dimensions of the logs
cm
55
Volume heated (45w/m³) at N.H.O.
m³
189
Log load frequency
h
1
Capacity of the ashpit
L
1,1
Weight
kg
147
Flue socket diameter
mm
200
Voltage (AC)
V
230
Frequency
Hz
50
Energy efficiency class
-
A
Energy efficiency index (EEI)
-
93
Note:
The values indicated in the above table are based on tests performed in accordance
with UNE-EN 13229 with logs with no more than 18% humidity and pressure conditions as
indicated in each case.
Содержание IF-800
Страница 1: ...IV 800 Instruction Book ...
Страница 25: ...DECLARATION OF PERFORMANCE 24 7 DECLARATION OF PERFORMANCE ...
Страница 26: ...DECLARATION OF PERFORMANCE 25 7 ...
Страница 27: ...CE MARK 26 8 CE MARK ...