background image

 

 

2  3 

Please note: 

With temperature and pressure, the history is shown referred to the current value. 
Here the display can optionally be in the form of a bar or line diagram according to the 
setting in the configuration mode. 

With humidity, wind speed, rainfall, hours of sunshine (8-day trend only) and brightness, the 
history is shown as the absolute value with the bottom line as the zero reference. In this 
case the display is always in the form of a bar diagram. 

 
Key functions (Allocation of touch screen fields, see page 11) 

Touch screen field 16 activates the selection mode (“SELECT”) 

Touch screen fields 17 and 18 switch over the display mode (8 days/24 h). 

 

3.2.7. 

Hours of sunshine 

The display field for the hours of sunshine (SUNSHINE DURATION) is situated at the bottom left 
of the display. Here the hours of sunshine are displayed in three ways: 

 

Total: 

 

 

  Last day 

 

   Current day 

 
 
 
 
 
 

 

1. The 

hours of sunshine 

are either displayed as a total (“h”; since the last deletion), the last 

hour (“h/day”) or the current day (“current h/day”). 

The following particular features should be noted: 

The hours of sunshine for the “last day” are always calculated at 0:00 hours. 

2. Here, 

the 

“Graph” symbol        

shows that the trend display for the hours of sunshine has 

been selected in the history field. It only appears if it has previously been selected (see 
3.2.6.:“History”). Only the 8-day trend is available. 

3. 

Sun symbol: indicates the 

current sunshine

, i.e. the symbol appears as long as the 

brightness sensor registers a brightness level above the threshold set in the configuration 
mode. 

 

Please note: 

From 0 to 99:59 h the time is displayed in the form hh:mm (resolution 1 min) 

From 100.0 to 999.9 h the time is displayed in the form hhh.h (resolution 1/10 h) 

From 1000 to 9999 h the time is displayed in the form hhhh (resolution 1 h) 

 
Key functions (Allocation of touch screen fields, see page 11) 

Touch screen field 19 switches over the display mode. 
Switching sequence: Total, last day, current day. 

If touch screen field 26 (“RESET”) is pressed briefly, the point in time at which the total value 
was last deleted will be displayed in the date and time field. 

If touch screen field 26 (“RESET”) is pressed for 3 seconds, the total value will be deleted. 

 
3.2.8. Brightness 

The display field for the current brightness (BRIGHTNESS) is situated at the bottom right of the 
display: 
 
 
 
 

1. The 

current brightness 

is displayed in lux or klux as appropriate. 

2. Here, 

the 

“Graph” symbol         

shows that the trend display for the brightness has been 

selected in the history field. It only appears if it has previously been selected. 

No key functions. 

 

3.2.9. Time/Date 

The display field for the time/date is situated at the bottom center of the display: 

 

              24h format  

 

                       12h format 

 
 
 
 

 

1. 

The time is displayed in hours and minutes and the date with the day of the week, day and 
month. Seconds are indicated by the two flashing dots. The display format is selected in the 
configuration mode. 

2. 

If a wake-up time has been activated, the alarm symbol will appear. If no wake-up time has 
been activated, the alarm symbol will be crossed out. 

 
Please note: 

The internal clock is configured as a normal yearly clock, i.e. February always has 28 days (no 
leap years).  

No key functions (all adjustments are made in configuration mode) 
 
3.2.10.  Special function keys 

The keys at the very bottom of the display allow functions to be activated directly or further 
display levels to be reached, e.g. configuration mode). 
 
 
 

 
Key functions: 

Touch screen field 23 (“

LIGHT OFF

”) switches the illumination off when it has been switched 

on. 

Touch screen field 25 (“

MIN 

”) activates the minimum value display. 

If pressed briefly, touch screen field 26 (“

RESET

”) shows in field 20/21 the point in time at 

which the total rainfall or the total hours of sunshine respectively was last deleted (see 
sections on Rainfall measurement/Hours of sunshine). 
If it is pressed for longer (approx.3 seconds) the total rainfall and the total hours of sunshine 
will be deleted (see: “Rainfall measurement ”/“Hours of sunshine”).  

Touch screen field 27 (“

MAX

”) activates the maximum value display. 

Touch screen field 29 (“

ALARM VALUES

”) activates the programming mode for the alarm 

values (see section “Programming mode”). 
If touch screen field (29) is pressed for a longer time (approx.3 seconds) the configuration 
mode will be activated (see section “Configuration mode”). 

 

3.3. 

Minimum/Maximum value display 

The minimum and maximum values of the trends together with the time of their occurrence are 
stored for all data ranges with the exception of the weather forecast and the time/date and can be 
reviewed in detail when desired. Values are stored from the time of commissioning or from 
deletion using the RESET function. 

 
 

Содержание WS-2510

Страница 1: ...emarkable It does not use any operating elements but is operated solely via a large touch sensitive LC display The display can be illuminated permanently or on a time basis so that it can be easily read under nearly all light conditions The weather station can optionally be powered by means of batteries or with the plug in power adaptor provided particularly recommended when the display is continu...

Страница 2: ...or 2 1 Current humidity of the selected outdoor sensor 3 Trend display for the temperature at the location of the respective sensor 4 Comfort zone indicator for the display of pleasant unpleasant climate 5 Display of the wind speed 6 Display of the current wind direction 7 Variation range display for variable winds 8 Display of rainfall umbrella means it is currently raining 9 Display of the curre...

Страница 3: ...e of the desk stand for when the unit is mounted on the desk When using this method any cables that are connected should be laid tidily in the slots of the desk stand in order to ensure an inconspicuous and orderly routing of the cables Commissioning After the batteries have been inserted or the unit has been connected to the power supply a short test of all the display segments is carried out all...

Страница 4: ...sors In the WS 2510 25 and WS 2510 19 outdoor sensors the magnet for activating the system is pressed into an opening provided for it in the rear of the housing The wind sensor WS 2510 15 is also activated by inserting a small magnet into the opening provided The magnet holder is located above the holding pipe fixing opposite the solar cell To insert the magnet in the WS 2510 16 rain sensor press ...

Страница 5: ...ew on page 4 The addressing can be set individually according to section 2 3 4 Since it is exclusively battery operated this sensor is suitable for use in dark inner rooms such as a garage a wine cellar or loft 2 3 6 WS 2510 27 temperature humidity sensor The WS 2510 27 requires two AA alkaline batteries for operation It enables the recording of garden pond or ground temperatures or similar by mea...

Страница 6: ...lumination will now remain switched on for the programmed time after the last key press As standard the illumination is active for 10s with battery operation and continuously on when using the AC power adaptor To switch off the illumination manually press the LIGHT OFF key bottom left field 23 The times for the illumination can be set up in configuration mode Cleaning mode As the display becomes d...

Страница 7: ...he required value between 0 and 99 seconds can now be set using the touch screen fields and It is possible to run through the display more quickly by pressing for longer When the required value has been set you can exit set up by pressing the END key The value is now stored Setting the temperature display units The display units for temperature are shown in touch screen field 4 at the top right Th...

Страница 8: ...tched between inHg hPa or mmHg Keypad beep on off The keypad beep can be switched on Sound on or off Sound off by touching field 12 Setting the display type for the history trend display By touching field 16 the history display can be switched between a bar and a line display Bar display Line display Setting the sunshine threshold value The set up field enables the brightness threshold to be set a...

Страница 9: ...viating from address 7 If an address is changed here after leaving the configuration mode the weather station will carry out a complete sensor synchronization for 6 minutes as at 7 30am Sensor protocol version 4 1 Sensor addresses The sensor addresses can be set up by touching the associated field 0 to 7 2 Protocol version The sensor protocol version can be changed over between 1 1 and 1 2 by touc...

Страница 10: ...en fields see page 11 Touch screen field 3 switches over between the display of temperature perceived temperature and dew point Touch screen field 4 selects the next sensor if available 1 8 Touch screen field 5 selects the previous sensor if available 8 1 3 2 2 Wind measurement field 7 The display field for the wind measurement is situated in the middle on the left Here the main wind direction the...

Страница 11: ... between displaying the absolute and the relative air pressure using touch screen fields 10 and 11 Please note A difference between the absolute and relative air pressure will only be displayed when the height corrected value for the relative air pressure has previously been entered 3 2 5 Weather forecast Based on years of experience in the development of weather measurement technology the weather...

Страница 12: ...display field for the current brightness BRIGHTNESS is situated at the bottom right of the display 1 The current brightness is displayed in lux or klux as appropriate 2 Here the Graph symbol shows that the trend display for the brightness has been selected in the history field It only appears if it has previously been selected No key functions 3 2 9 Time Date The display field for the time date is...

Страница 13: ...ually by pressing the END key the min max display will be terminated automatically 2 minutes after the last key has been pressed and the unit will revert to normal display mode Only the maximum value display is available for the rain and wind sensor In the case of the rain sensor the display modes for the maximum value display are adapted as follows Total maximum value that occurred in the last 24...

Страница 14: ...r pressure 700 hPa to 1099 hPa 525 mmHg to 824 mmHg 20 65 inHg to 32 42 inHg 3 4 3 Setting the wake up times Please note The wake up time including the associated day can only be edited in the MAX alarm value display The day for which the wake up function is to be set can be set using the DAY field field 27 The display means that the wake up time set applies to all 7 days of the week daily wake up...

Страница 15: ...nsmitted readings are No reception The distance between transmitter and receiver is too great Reduce the distance between the transmitter and the receiver No reception dense shielding materials are positioned between the transmitter and the receiver thick walls reinforced concrete Find another position for the transmitter and receiver See also section 6 Range Transmitter batteries are discharged C...

Страница 16: ...C size alkaline batteries Plug in power supply 7 5 V 500 mA Dimensions W x H x D Housing 10 1 x 8 3 x 1 4 257 x 211 x 36 mm 10 Explanation of terms Perceived temperature see Wind chill Dewpoint Temperature point that is dependent on the conjunction of a specific air pressure a specific temperature and a specific humidity At this temperature the humidity in the air begins to condense the so called ...

Страница 17: ...t a temperature of 77 F 25ºC for example to be too dry e g heating air and one above 60 to be oppressive 11 Warranty Information La Crosse Technology provides a 1 year warranty on this weather station Contact La Crosse Technology immediately upon discovery of any defects covered by this warranty Before sending the weather station in for repairs contact La Crosse Technology The weather station will...

Страница 18: ...g errors or their consequences All trademarks and patents are acknowledged THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION Touch Screen Wireless Weather Station WS 2510 Operating instru...