specified here in addition, so that the steps are not added to the display of
the Position!
Max. Position:
The value of the maximum available position. It can be a maximum of
250,000, which means a 250mm path with 0.001mm steps, which is
sufficient for all focusers. To avoid collisions, do not use a value greater
than what our focuser allows.
Set Actual Position:
It is possible to overwrite the current position. The value entered here will
be the current position entered in the device! It is advisable to use it with a
fully wrapped focuser and with a value of 0 so that the limits cannot be
exceeded.
Danger of collision!
CurrentMove (mA):
The value of the moving current is in milliamperes. In the case of FMC,
this value can be increased to 1000mA.
Current Hold (mA):
The value of the holding current is in milliamperes. In the case of the FMC,
this value can be increased to 1000mA, but in practice, we should not use
a holding current higher than necessary, in order to avoid undue heating of
the controller. 160-200mA is sufficient in almost all cases.
Reverse Direction:
It is used to set the direction of rotation of the motor. Increasing the
position value should cause the engine to move the draft outward. If this is
not the case, the direction of rotation must be changed, check it.
Command buttons:
The
Goto
by pressing the button, it is possible to send the draft to the desired
position under Target pos. after filling in the field.
LACERTA
FMC
14
2022
Содержание FMC
Страница 5: ...LACERTA FMC 5 2022 ...
Страница 6: ...LACERTA FMC 6 2022 ...
Страница 7: ...LACERTA FMC 7 2022 ...
Страница 8: ...Installing the ASCOM driver LACERTA FMC 8 2022 ...
Страница 10: ...LACERTA FMC 10 2022 ...