1. Install spout body into mounting hole and install

washer and lock nut from underneath the mounting

surface (avoid damaging mounting surface by over-

     tightening).

5

2. Mount the hand dryer operating box within 21” of the spout

location, and connect it to the spout with flexible hose.

For best performance,  keep the connecting hose straight if

possible, free of unnecessary turns and twists.

For ADA compliant installation, refer to ADA requirements.

a. Mark the location of mouting screws, and install

the mounting bracket,  using the provided or suitable

hardware.

b. Hook the back of the hand dryer box  onto the mounting

bracket and secure the bottom of the hand dryer box

to the wall.

c. Feed the sensor cable through the flexible hose, making

sure the cable is not kinked, screw the hose onto the tail

of the spout.

d. Connect the sensor cable to the hand dryer box

via a metal 3-pin aviation plug and hand-tighten the base.

e. Make sure to place the sensor cable in the slot on the

hose coupling sleeve, and tighten the hose clamp.

Do not pinch the senser cable.

3. Plug power cord to wall socket.

1.

2b.

2a.

2d.

!

2e.

3.

2c.

Содержание ZOOM EX42-D1

Страница 1: ...ary Revised 02 15 2023 LACAVA CHICAGO IL USA 773 637 9600 INFO LACAVA COM LACAVA COM EX42 SENR replacement sensor Power Supply Power supply Voltage 120V AC Frequency 50 60 Hz Power 1100W max Sensing d...

Страница 2: ...ruction for commercial grade durability Includes spout flexible supply hose operating box and installation hardware Easy electric plug in power supply HEPA filter removes 99 99 of particles as small a...

Страница 3: ...s planos proporcionados en este documento tienen el prop sito de dar al usuario una idea del producto y no est n hechos a escala Los tama os de pulgadas se redondean al m s cercano 1 16 4 100 32 1 1 4...

Страница 4: ...glosamiento de Partes Note Please reference this sheet and the corresponding part number when requesting parts Nota Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes 1...

Страница 5: ...A dedicated 120 V AC 15A GFCI minimum outlet must be provided properly grounded and no more than 4 ft from the installation of the dryer assembly 2 If no GFCI outlet is provided contact a licensed ele...

Страница 6: ...tion refer to ADA requirements a Mark the location of mouting screws and install the mounting bracket using the provided or suitable hardware b Hook the back of the hand dryer box onto the mounting br...

Страница 7: ...which may shorten the service life of the motor A clogged up filter reduces the air flow volume and puts unnecessary stress on the blower motor For relatively clean and dry environments the HEPA filt...

Страница 8: ...etergente suave es decir el jab n para lavar la vajilla para la limpieza Si se utiliza otro limpiador revise la etiqueta para asegurarse de que es seguro para el uso del material para su limpieza y si...

Отзывы: