INSTALLER’S MANUAL
VOUGEOT - VOLNAY
ELECTRICITY
It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting from non-compliance with this requirement or incorrect grounding.
Connect the equipotential bonding terminal (
N
, Figure 27).
Before connection, check that the
:
Mains voltage is compatible with the appliance’s rated
voltage and thermal output.
Connection :
-
Use a 3-wire grounded cord rated for 13 A or 4-wire
rated for 30 A 125 / 250 VAC, type SRD, SRDT, S,
SO or ST.
-
Where local Codes do not permit grounding through neutral, use a 4-wire power supply cord or “pigtail” kit. Cord
must be agency approved for use with household ranges.
-
Remove access door
O
(Figure.28, gas oven range) or
P
(Figures 29 and 30, gas and electric range).
-
Remove cable clamp and loosen supply cord mounting screws on the terminal block.
-
Connect to terminal block in accordance with figure 32.
-
Secure the cable by means of cable clamp, item
Q
(Figure 31).
- Refit
access
door
THE APPLIANCE WHEN INSTALLED, MUST BE
ELECTRICALLY GROUNDED IN ACCORDANCE
WITH THE LOCAL CODES OR The National Electrical
Code, ANSI/NFPA 70-1996 or latest edition.
ALL WORK ON OR REPAIR OF AN APPLIANCE
MUST BE CARRIED OUT BY A QUALIFIED
INSTALLER.
IMPORTANT
N
Fig. 27