SERVICE INSTRUCTIONS :
- Lubricating gas valve.
If the gas taps tends to stick slightly, you may follow this procedure :
1 - Shut off the valve and / or the main electrical supply of the unit.
2 - Take out the knob corresponding to the gas
valve to be greased.
3 - Unscrew the head from the body of the
burner valve.
4 - Grease the tap shaft (High temperature
lubricant, for example : SILICAL GEL ™
BARBAHL).
Caution! Any excess grease should be removed.
Reverse operation 3 to 1 (in that order) to put valve
and knob back on.
- Limiting thermostat :
To access internal components, lift and secure top.
Press pushbutton item
U
(Figure 34) in order to reset
the limiting thermostat.
Note:
ALWAYS IDENTIFY
the reason why the
thermostat tripped.