ELECTRICITY
It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting from non-compliance with this requirement or incorrect grounding.
Connect the equipotential bonding terminal (
N
, Figure 25).
Before connection, check that the
:
Mains voltage is compatible with the appliance’s rated
voltage and thermal output.
Connection :
Use a 3-wire grounded cord rated for 13 A or 4-wire rated for 30 A 125 / 250
VAC, type SRD, SRDT, S, SO or ST.
Where local Codes do not permit grounding through neutral, use a 4-wire power
supply cord or “pigtail” kit. Cord must be agency approved for use with
household ranges.
Remove access door
O
(Figure.25, gas oven range) or
P
(Figure 26, 4 electric
oven range).
Connect to terminal block in accordance with figure 28.
Secure the cable by means of cable clamp, item
Q
(Figure 27).
Refit access door
THE APPLIANCE WHEN INSTALLED, MUST BE
ELECTRICALLY GROUNDED IN ACCORDANCE
WITH THE LOCAL CODES OR The National Electrical
Code, ANSI/NFPA 70-1996 or latest edition.
ALL WORK ON OR REPAIR OF AN APPLIANCE
MUST BE CARRIED OUT BY A QUALIFIED
INSTALLER.
IMPORTANT
Fig 26
O
N