INSTALLER’S MANUAL
Adjusting reduced flow of hob burners :
A
fter connection or change of gas, it is crucial to modify this adjustment :
►
R
emove the knob.
►
L
ight the appropriate burner.
►
A
djust to minimum setting.
►
U
se a small screwdriver to set the adjusting screw
G
/figure
8
.
N.B
: Flame is reduced to ¼ of its size in the minimum setting, the burner must remain lit when
changing from maximum setting to minimum setting.
Adjusting the safety devices for each thermocouple of the hob: :
I
f the burner goes out, having kept the control knob pushed in for roughly twenty seconds, check
that
:
-
T
he magnetic head grip the valve moderately.
-
T
he flame touches the point of thermocouple
H
figure
8
,
-
T
he thermocouples and magnetic heads are absolutely clean.
9
H
CHANGE OF GAS
Adjusting the primary air of hob burners :
►
P
osition the burner bodies and flame diffusers in their respective locations.
►
A
djust the air ring
F
/ figure
7
, tabel
3
.
N.B
: Normal flames are bluish green except for natural gas flames which are violet.
Table 3
Burners
SF
F
I
GAS
Pressure
Oppening / inches
Natural gas
6» WC
2,5 /
1
/
8
2,5 /
1
/
8
max
L.P. propane
10» WC
3,5 /
1
/
8
max
max
G
8
Notice provisoire Beaune - Bussy UL - FT164h - Date : 16/10/12
14/42
Содержание BEAUNE
Страница 6: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 6 42...
Страница 8: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 8 42...
Страница 30: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 30 42...
Страница 34: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 34 42...