background image

 

Operating Instructions for pressure transmitter  
PASCAL CS

, Type Series CS2100 and CS2110

 

 

 

 Do you have questions about this device? Call our hotline at: +49 (0) 4408 804-444 

LABOM Mess- und Regeltechnik GmbH · Im Gewerbepark 13 · 27798 Hude · Germany 

Tel.: +49 (0) 4408 804-0 · Fax: +49 (0) 4408 804-100 · e-mail: [email protected] · www.labom.com

 

BTA 060

Rev 1K1

Page 1/18

 

 

 

 

Table of contents 

1

 

General Information ..................................................................................................... 2

 

1.1

 

Intended Use ........................................................................................................ 2

 

1.2

 

General Safety Notes............................................................................................ 2

 

1.3

 

CE Marking ........................................................................................................... 2

 

2

 

Transportation and Storage ......................................................................................... 2

 

3

 

Installation and Commissioning ................................................................................... 2

 

3.1

 

Electrical Connection ............................................................................................ 3

 

3.2

 

Adjusting the display unit ...................................................................................... 4

 

3.3

 

Devices with flush mounted diaphragm ................................................................ 4

 

4

 

Operation ..................................................................................................................... 5

 

4.1

 

Setup / Parameterization ...................................................................................... 5

 

4.2

 

Maintenance ......................................................................................................... 5

 

5

 

Removal....................................................................................................................... 5

 

6

 

User Manual................................................................................................................. 6

 

6.1

 

System operating principles.................................................................................. 6

 

6.2

 

Main menu .......................................................................................................... 10

 

6.3

 

Basic menu (

bASE

) ............................................................................................. 10

 

6.4

 

Display menu (

diSP

) .......................................................................................... 13

 

6.5

 

Switch-point menu .............................................................................................. 14

 

6.6

 

System menu...................................................................................................... 17

 

6.7

 

Overview of the menu tree.................................................................................. 18

 

 

Содержание PASCAL CS

Страница 1: ...Table of contents 1 General Information 2 1 1 Intended Use 2 1 2 General Safety Notes 2 1 3 CE Marking 2 2 Transportation and Storage 2 3 Installation and Commissioning 2 3 1 Electrical Connection 3 3...

Страница 2: ...ble EU Directives for placing products on the market within the European Union The following guideline applies to model series PASCAL CS21xx EMC Guideline EMC 2004 108 EG 2 Transportation and Storage...

Страница 3: ...switching output 2 Pgm1 2 programming pins Figure 1 Pin assignment for M12 circular connector device side 3 1 1 Connecting the switching outputs optional The switching outputs are potential free They...

Страница 4: ...nless steel housing with one hand and turn the display unit with the other hand into the wanted position The turning angle is limited by an internal limit stop Do not try to force the display unit bey...

Страница 5: ...configure it with a communication modem and the PC Software COMLINE S This is described in a separate manual 4 2 Maintenance When properly installed in accordance with applicable specifications this...

Страница 6: ...y the LED flashing When there is no button pressed the output states are displayed 6 1 2 Display mode Measured value screen When the device is switched on it goes into display mode The currently measu...

Страница 7: ...to display mode At the end of a menu typically the rEt item you return to the first menu item by repressing the down arrow button again Similarly you can jump from the first menu item to the end of th...

Страница 8: ...the rEt item which allows you to return to the next higher menu level The middle button stores your selection Stor appears on the display to confirm that the value has been stored and the device retur...

Страница 9: ...the previous value You confirm the selected digit with the middle button and proceed to the next digit You can cancel the value entry at any time by pressing both arrow buttons simultaneously The dev...

Страница 10: ...system data versions serial number reset to factory settings Return Return to display mode Table 3 The items in the main menu 6 3 Basic menu bASE The basic menu contains the following items Display D...

Страница 11: ...of the measuring range with the teach lower range menu item tlr When the menu item is selected the entry points to rEt To trigger the function go to YES with one of the arrow buttons and confirm with...

Страница 12: ...m in this menu Resetting a pointer is confirmed by showing on the display Display Designation Description Value of min max pointer Value of min max pointer in the selected measuring unit Clear Reset t...

Страница 13: ...two ways either by pressing the middle button in display mode or alternately with the measured value When displayed alternately with the measured value the display periods for the measured value and...

Страница 14: ...shown on the display will appear flashing e g 99 99 when two decimal places are set for a measured value of 110 mbar 6 5 Switch point menu The switch point menu contains the functions for setting the...

Страница 15: ...hen you select a frame function the menu items for switch point and reset point are replaced by the upper and lower frame limits The minimum difference of the frame limits is also 0 5 of the measuring...

Страница 16: ...If the pressure is above the switch point the switch is open At the lower range limit the switch is closed Frame normally open Inside of the frame the switch is closed At the lower range limit the swi...

Страница 17: ...enu Due to the limited number of alphanumerical segments on the display hardware and software versions are split into two separate items and serial number into four items 6 6 2 Reset to factory settin...

Страница 18: ...Display direction 0 normal 180 turned Setting the decimal places zero to three fixed decimal places or automatic Configuring the switching outputs only if available Switch point or upper frame limit o...