High temperature pressure gauges 

Type series BX1007 

 

 

 

LABOM Mess- und Regeltechnik GmbH   Im Gewerbepark 13   27798 Hude   Germany 

BA_036_2019-11_10.01 

Hotline: +49 4408 804-444   Fax: +49 4408 804-100   e-mail: [email protected]   www.labom.com 

Page 1/4 

Operating Instructions 

 

1

 

General Information....................................................................................................... 2

 

1.1

 

General Safety Notes .............................................................................................. 2

 

1.2

 

Intended Use ........................................................................................................... 2

 

2

 

Transportation and Storage .......................................................................................... 2

 

3

 

Installation and Commissioning .................................................................................. 2

 

3.1

 

Mechanical Installation ............................................................................................ 2

 

4

 

Operation ........................................................................................................................ 3

 

4.1

 

Zero-point correction ............................................................................................... 3

 

4.2

 

Maintenance / Service ............................................................................................. 3

 

5

 

Disassembly ................................................................................................................... 4

 

 

Содержание BX1007 Series

Страница 1: ...9 4408 804 444 Fax 49 4408 804 100 e mail sales labom com www labom com Page 1 4 Operating Instructions 1 General Information 2 1 1 General Safety Notes 2 1 2 Intended Use 2 2 Transportation and Storage 2 3 Installation and Commissioning 2 3 1 Mechanical Installation 2 4 Operation 3 4 1 Zero point correction 3 4 2 Maintenance Service 3 5 Disassembly 4 ...

Страница 2: ...he origi nal packaging Avoid exposure to shocks and excessive vibrations Permissible storage temperature 0 70 C 3 Installation and Commissioning Ensure that the device is suitable for the intended application with respect to pressure range overpressure limit media compatibility temperature range and process connection 3 1 Mechanical Installation Use gaskets if required that are suitable for the pr...

Страница 3: ...ambient temperature 10 70 C 4 1 Zero point correction Small measuring errors or deviations caused by difference in level between pres sure gauge and point of measurement can be corrected on measuring devices with micro control position pointers To do so turn the adjusting screw on the pointer hub see figure 4 Similarly a displacement of the zero point caused by use and long service life can be cor...

Страница 4: ... 912 A2 70 quality for the two threaded holes as shown on the drilling diagram to push the device out of the process and ensure ease of removal You can order these screws as an accessory Warning Opening pressurized lines might cause severe injuries Danger of severe injuries or damage Relieve the process pressure before attempting to remove the device Shut off the pressure supply for all feed lines...