background image

6

Visit 

www.labnetinternational.com

  for additional product and technical information.

5. Labnet Enduro™ GDS II Gel Documentation System Installation Guide

Remove the Labnet Enduro 
GDS II Gel Documentation 
System from its packaging.

1.

Identify the Labnet USB and 
connect it to a Microsoft® 
Windows® 7, 8, or 10 
computer.

On the USB, find the folder 

“Enduro Imaging Files\
Enduro_v_XXX” and open it. 
Double click on the 

Setup

 file. 

(You may see a message pop 
up that says “Do you want to 
allow the following program 
from an unknown publisher 
to make changes to this 
computer?” Select 

Yes

.)

Click 

Next

 to begin the Setup 

Wizard.

Select 

Enduro GDS II

, then click 

Next

.

Select your installation 
location, then click 

Next

.

Click 

Install

 to continue with 

the installation.

Click 

Next

 to begin the driver 

installation.

To continue, accept the license 
agreement. Then click 

Next

.

Select the UV wavelength of 
the system.

After the installation is 
complete, click 

Finish

.

2.

3.

4.

5.

6.

8.

9.

10.

11.

12.

To continue, accept the license 
agreement. Then click 

Next

.

7.

Содержание Enduro GDS II

Страница 1: ...Labnet Enduro GDS II and Enduro GDS Touch II Gel Documentation System Instruction Manual Catalog Numbers GDS2 1302 GDS2 1365 GDST2 1302 GDST2 1365...

Страница 2: ...gulatory Compliance 4 3 Specifications 5 4 System Placement 5 5 Labnet Enduro GDS II Gel Documentation System Installation Guide 6 6 Labnet Enduro GDS Touch II Gel Documentation System Installation Gu...

Страница 3: ...es imaging software calibration files 3 power cables 110V 220V US EU UK Please select the correct one for your region The Labnet Enduro GDS Touch II Gel Documentation System includes the following com...

Страница 4: ...tion devices such as the safety switch on the light cabinet apparatus are working properly If not discontinue use until the device s are properly repaired Use only UV lamps in the transilluminator Ele...

Страница 5: ...gigabyte GB RAM 32 bit or 4 GB RAM 64 bit 16 GB available hard disk space 32 bit or 20 GB 64 bit Operating system Windows 10 Processor 1 gigahertz GHz or faster processor Intel RAM 2 gigabyte GB for 3...

Страница 6: ...Setup file You may see a message pop up that says Do you want to allow the following program from an unknown publisher to make changes to this computer Select Yes Click Next to begin the Setup Wizard...

Страница 7: ...S II system using the switch in the back Wait about 20 seconds before proceeding to the next step Launch the capture software The first time you run the Enduro Capture Software you will receive the me...

Страница 8: ...tem from its packaging Locate the tablet computer Remove the wing nuts from the back of the tablet Mount the tablet on the system Secure the tablet in place with the wing nuts Connect the mini USB cab...

Страница 9: ...o GDS II Gel Documentation System Labnet Enduro GDS Touch II Gel Documentation System EtBr Gel UV 302 or 365 UV 302 or 365 Sybr Safe Gel UV 302 or 365 Epi Blue Coomassie Gel Visible Visible Requires o...

Страница 10: ...op window to your desired size and then select Crop ROI from the bottom of the screen If you do not want to crop select Cancel Rotate Rotate allows you to rotate your image one of four ways Right 90 d...

Страница 11: ...the live image so you can make sure your gel is vertically and horizontally straight Select ROI Select ROI has two functions Select ROI then select Image Capture this results in a final cropped imaged...

Страница 12: ...ighlighted annotation object Font Color Line Width Once an annotation object is selected using the pointer you can edit the line width and the color and in the case of text the font Settings Tab The p...

Страница 13: ...d in the supplied instruction manual This warranty does not cover damage caused by accident neglect misuse improper service natural forces or other causes not arising from defects in original material...

Страница 14: ...not be disposed of with domestic waste Consequently the buyer shall follow the instructions for reuse and recycling of waste electronic and electrical equipment WEEE provided with the products and av...

Страница 15: ...t your local Corning sales office Corning Incorporated Life Sciences 836 North St Building 300 Suite 3401 Tewksbury MA 01876 t 800 492 1110 t 978 442 2200 f 978 442 2476 www corning com lifesciences A...

Отзывы: