9
LOKASET R
| Installation and Operation Instructions | D18067Be
Pairing the central unit and the transmitter:
The Lokaset R central unit and transmitter form a device pair. Any
subsequent spare part deliveries require re-pairing.
Pair the devices by simultaneously pressing the alarm reset but-
ton and powering the central unit. All lights on the central unit
will fl ash, indicating that the devices are being paired.
Press the function button (p. 8) on the Lokaset R transmitter.
The green light (POWER) and red light (ALARM) are on and the
blue light (SIGNAL) fl ashes. Complete the process by pressing the
central unit reset button again. The blue light (SIGNAL) remains
on and fl ashes every 8 seconds to indicate the test mode. The
Lokaset R central unit and transmitter are now paired. The device
returns to the normal operating mode after 5 minutes.
6. Lokaset R – Alarms
Tank full alarm:
Red light (1) is on (continuous buzzer sound)
a) Reset the alarm (2)
b) Arrange tank disposal
1
2