6.
Commissioning
The device can be commissioned in the two ways described in the following sections:
Simple commissioning
Commissioning through the browser-based user interface
1 Display
2 Reset button
3 Type plate with the
serial number
Figure 15. User interface description
6.1.
Simple commissioning
Ensure that the sensors have been installed and connected in the control unit in
accordance with the instructions in the previous paragraphs.
Connect power to the control unit.
A message is shown in the control unit
display: NO SENSORS.
Figure 16. Initial start-up
Briefly press the sensor identification
button through the hole indicated in the
figure, using a small screwdriver or pen.
Figure 17. Sensor identification button.
The control unit display shows the message
"Detecting sensors, 0 sensor(s) found" and
three dots begin cycling at the bottom of the
display.
Figure 18. Sensor identification.
Installation and Operating Instructions | idOil-D30
18/51