background image

12

12

Needle combination of hygiene modules

5er-Magnum-Hygienemodul (0,3 mm)

Needle

Art-No:

The 5th-Magnum hygiene module contains 2 + 3 
needles with a diameter of each 0.3-mm that are 
aligned in a double row.

Practical tip:

 To achieve a more intense lip 

contour pigment lengthwise, for shading and colour 
filling widthwise.

PL-500 Control: E-0405M

Application:

  Eyebrow shading and wider eyeliner

  Lip shading and lip colour filling

 Scars and areo

7th-Round hygiene module (0,3 mm)

Needle

Art-No:

The 7th hygiene module has 7 circularly arranged 
needles of each 0.3 mm. 

Practical tip:

 Idealy suited for wide defined contour 

lines and shading. Due to the multitude of needles the 
customers experience less pain. Ideal colour injection 
and shorter treatment time.

PL-500 Control: E-0407

Application:

• 

Broader lip contour

• 

Colour filling of the lips

• 

Areola and scars

9th-Magnum hygiene module (0,3 mm)

Needle

Art-No:

In the 9th-Magnum hygiene module the needles are 
positioned horizontally, similar to the 4er-Flat need-
les. The first row contains 4, the second row (arran-
ged closely behind) contains 5 needles. Each needle 
with a diameter of 0.3 mm.

Practical tip:

 If a broader line is desired, make sure 

that the flat needle is traced exactly at a right angle 
to the line and the handpiece is held vertically to the 
skin to enable all needle tips to inject the colour at the 
same depth.

PL-500 Control: E-00409

Application:

•  

Ideal for shading of eyebrows, areola and 
scars

  Perect for colour shading and colour filling of  

the lips

Содержание PL-500 Control

Страница 1: ...User s manual LaBina PL 500 Control www LaBina24 de...

Страница 2: ...rator is obliged to comply with the principles of cleanliness and hygiene as well as to utilise so lely sterile disinfected materials Further information is provided in the chapter important hygiene a...

Страница 3: ...nnot be guaranteed Sup plies must not be used after the expiration date The brackets and protective caps of the handpiece must also be cleaned and disinfected immediately before the treatment of every...

Страница 4: ...signs of damage if the device does not run properly after a long period of storage beyond the mandatory temperature range in case of damages caused by improper transport The device should be transferr...

Страница 5: ...5 N H F E K P M A K G B D Rear of the control unit Front of the control unit...

Страница 6: ...sidues or scars could remain after the remo val During the first 4 to 6 weeks the intensity of the injected pigments is reduced to the permanent level This is usual as the epidermis upper skin layer i...

Страница 7: ...stored in the original packaging Utilisation of pigments The module must be filled with 2 to 3 drops of colour Alternatively the tip of the module can be immersed into the colour for 2 to 3 seconds Th...

Страница 8: ...www Labina24 de...

Страница 9: ...Lip contour and fine inward lip shading Test point for allergy tests 1st Micro hygiene module 0 18 mm Needle Art No The needle diameter of the 1st Micro hygiene mo dule similar to the 1st Liner hygien...

Страница 10: ...ely and are bundled closer to each other Practical tip Due to the closer bundling the 3rd Outline needle is not perceived to be as sharp as a 1st needle It enters the skin particularly well and traces...

Страница 11: ...shading Shading of lip edges in case of narrow lips Shading of full lips 3rd and 5th Slope hygiene module 0 4 mm Needle Art No In a sloping needle type 3 or 5 needles are aligned side by side at an a...

Страница 12: ...e of needles the customers experience less pain Ideal colour injection and shorter treatment time PL 500 Control E 0407 Application Broader lip contour Colour filling of the lips Areola and scars 9th...

Страница 13: ...A make up that accompanies you regardless which weather...

Страница 14: ...nd the device must never be directly soaked in a desinfectant agent as this may cause inner parts to corrode If a protective cap is used for storage purposes during a treatment the protective cap must...

Страница 15: ...ciousness dizziness Particular caution is necessary in the following cases If the patient suffers from herpes simplex a pigmentation of the lips usually causes herpes labialis cold sores A prior consu...

Страница 16: ...d oxidising acids e g peracetic acid lyes e g sodium hydroxide ammonia all substances with a pH level higher than 7 aromatic halogenated hydrocarbons e g phenol chloroform as well as acetone and petro...

Страница 17: ...Control unit Rated voltage 15 V DC Power input 7 VA max Wall wart as stated on the type plate Level of protection 2 Operating conditions Ambient temperature 10 C to 35 C Relative humidity 30 to 75 17...

Страница 18: ...device that is free of charge for the duration of the repair Distribution PERMANENT Line GmbH Co KG Complementary PERMANENT Line Schneider Kosmetik GmbH Mengeringh user Str 15 34454 Bad Arolsen Deutsc...

Отзывы: