LM3612 PRINT & APPLY SYSTEM
USERS MANUAL
Page 34
Made in the U.S.A.
© 2021 LabelMill
06/01/2021 Model LM3612
QUICK START GENERAL SETUP
(TAMP APPLICATION)
1. Inspect applicator system and verify all cables are installed properly.
2. Web system with labels.
3. Turn power switch on.
4. Turn printer on & load label files.
5. Press “PROGRAM”
6. Enter Defaults.
7. Select "PRODUCT SENSOR"
8. Enter sensor parameters.
9. Press "TAMP SETUP"
10. Set tamp duration to .500 and set Head up switch to “N.O.”
11. Press "CYCLE TYPE"
12. Set cycle type to “Tamp Before Feed”
13. Press "EXIT"
14. System is now ready for set up of advanced features and options.
SETUP OF KEY FEATURES
HOW TO SET UP AN ASYNCHRONOUS APPLICATION
•
“TAMP”
Determine the following and select it in the software
1. Type of application mode. MENU “CYCLE TYPE”
2. Tamp before or after feed (before feed is standard)
3. Enter a value in the tamp duration (start with 00.500).
4. Set head up limit switch, normally open is standard.
5. Use the product delay to “MOVE” the label placement on the product.
The asynchronous application mode is used to apply labels to products that are either stationary or moving at a constant
speed when the label application is to take place.
3-06