Page 8
Step 3: Calibrate the End of Roll Sensor/Opaque Label Sensor
•
Place both direction switches to the center
-
off position (illustrated by the
“|”
symbol).
(FIG. 16)
•
Place the label liner only (no label) into the label gap sensor.
(FIG. 21)
•
Turn the Photocell Adjust knob located on the left hand side of the counter until the green Photocell Ad-
just LED above the Counter Reset button illuminates.
(FIG. 16)
•
Remove the label liner from the label gap sensor.
CALIBRATING THE ULTRASONIC SENSOR (RRC
-
400
-
U Model Only)
•
Once the labels have been threaded through the label sensor, press and hold the
“
T
”
button, located on
the front of the sensor, until the green and yellow LED
’
s flash simultaneously.
(FIG. 17)
•
Release the
“
T
”
button and advance the label stock through the sensor until the LED
’
s stop flashing and
only the green LED remains illuminated.
(FIG. 17)
•
Manually rotate the supply roll until the first label you want to count is properly positioned.
•
Reset the counter to 0 and start the unit.
(FIG. 16)
FIG. 14
FIG. 15
FIG. 16