4) PROGRAM SELECTORS
The program selector allows the door user to select the operating mode.
The following can be used, according to the choice: manual selector integrated in Neptis operator side, EV-MSEL key mechanical
selector or N-DSEL digital programmer.
Each program selector is described in details below.
4.1)
MANUAL PROGRAM SELECTOR
The 3-position manual program selector is the basic solution provided for onboard operator.
= Bi-directional automatic program
The door automatically opens when each opening control activates.
= Free manual door
The automatic operation is disabled and door can be manually open.
=
Night lock program
The door can only be open by OPEN input or radio control, if applicable.
Open door program
The door stops in complete opening position.
The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes.
Open door program
The door stops in complete opening position.
Free manual door
The automatic operation is disabled and door can be manually open.
Bi-directional automatic program
The door automatically opens when each opening control activates.
Single-direction automatic program output only
To exclude the incoming detection on external radar input
Night lock program
The door can only be open by OPEN input or radio control, if applicable.
OPERATING MODE
Insert and rotate the key in EV-MSEL selector to select the program desired.
6
Can have two different
behavior, depending on
the programming of the
control unit.
Position
I
Position
0
Position
II
4.2) EV-MSEL MECHANICAL KEY SELECTOR