![Labcotec LCJ1-SK4 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/labcotec/lcj1-sk4/lcj1-sk4_operating-instructions-manual_667627003.webp)
OPERATING INSTRUCTIONS
(EN)
CABLE CONNECTOR LCJ1-SK4
2 / 11
DOC001792-ML1-0 | 21.3.2019
TECHNICAL DATA
LCJ1-SK4
Dimensions
Ø 26,5 x 115 mm
Weight
47 g
Temperature
Ambient temperature: -40 ... +125 °C
Protection
IP68
Ex-classification
Simple apparatus according to IEC/EN 60079-11 (Intrinsic Safety i)
II 1G Ex ia IIA T4 Ga
Ui = 30 V, Ii = 500 mA, Pi = 1 W, Ta = -40 °
C …+
125 °C
Components (see Figure 1)
(1)
Housing
PA66 GF UL94 V0 GWT 960°C
(2)
Terminal block
3-pole, core cross section 0,5-4,0 mm
2
PA66 GF UL94 V0 GWT 960°C
(3)
Cable glands (*)
2 pcs, M20 x 1,5 PA66 UL94 V2 GWT 850°C
(4)
Seal (*)
2 pcs, TPE, for cable diameter 5-13,5 mm
(5)
O-rings (*)
2 pcs, silicone, 24 x 19,3 x 1,5 mm
(*) O-rings and seals of cable glands are mineral oil resistant
If shielded cable is used, shield must be cut and insulated properly
Figure 1. LCJ1-SK4 cable connector