EXAMPLE
(RX) SSB FILTER ADJUSTMENT: (CHANGE FIL-3)
Set FIL-3: Bandwidth: 2.4 kHz; Passband: 600Hz to 3kHz
1.
Long-Push
E
to enter filter adjustment menu. The parameter to be
adjusted is shown in the bottom line of the display.
Menu Up Menu Down NumFil Sel
RX SBB FIL-1 LF 600
E
2.
Push
N>
NumFil
until
FIL-3
is selected (in the bottom line).
Menu Up Menu Down NumFil Sel
RX SSB FIL-3 LF 600
3.
Push
N>
Sel
once to select “HF”. The display might now look like this:
“
RX SSB FIL-3, HF2700
”. (‘2700’ might be any other value).
Menu Up Menu Down NumFil Sel
RX SSB FIL-3 HF 2700
4.
Rotate
M
TUNE/MULTI
to change 2700 to 3000
(notice the frequencies are in Hz, not in kHz).
Menu Up Menu Down NumFil Sel
RX SSB FIL-3 HF 3000
5.
Push
E
to save changes and exit the filter adjustment menu.
6.
CHECK YOUR WORK: Push
E
a few times until
FIL-3
is selected.
It should now display 2.40 k.
E
×
3