background image

PLM Series Quick Start and Field Reference Guide rev 1.0.6

Table of Contents

3

    

7.2.4 AC input ..........................................................................................................................................27

8. Technical Specifications ..........................................................................................................................28

9. Warranty ....................................................................................................................................................30

Содержание PLM Series

Страница 1: ...Rev 1 0 6 Item no QSG PLM Operation Manual PLM Series Powered Loudspeaker Management systems Quick Start and Field Reference Guide...

Страница 2: ...n 7 4 2 1 Lab gruppen documents 8 5 Installation 9 5 1 Unpacking 9 5 2 Mounting 9 5 3 Rear Mounting 9 5 4 Cooling 11 5 5 Operating Voltage 11 5 6 Grounding 12 6 Quick Start Tutorial 13 6 1 Introductio...

Страница 3: ...PLM Series Quick Start and Field Reference Guide rev 1 0 6 Table of Contents 3 7 2 4 AC input 27 8 Technical Specifications 28 9 Warranty 30...

Страница 4: ...s intended to alert the user to presence of important operating and service instruc tions in the literature accompanying the product 3 1 1 WARNING 3 1 2 CAUTION To reduce the risk of fire or electric...

Страница 5: ...for long periods of time 13 Do not connect the unit s outputs in parallel or series with any other unit s output Do not connect the unit s output to any other 14 voltage source such as battery mains s...

Страница 6: ...that to which the receiver is connected Check if the affected unit complies with the EMC limits for immunity CE labeled If not address the problem with the manufacturer or supplier All electrical prod...

Страница 7: ...section builds on the foundation of the road tested FP and legendary fP Series providing the same powerful tight bass and transparent high frequency response In addition the PLM Series establishes new...

Страница 8: ...ndum This document covers those features and functions that are unique to the PLM in the Lake Controller software application Dolby Lake Controller User Manual This document provides detailed informat...

Страница 9: ...l Data PLM 14000 Technical Data PLM 10000Q A E Specifications We recommend that you keep the original carton and all other packaging materials to facilitate shipping of the PLM should the need arise 5...

Страница 10: ...k rails Two mounting methods are possible note that the method shown in figure 5 3b additionally provides extra security against unauthorized removal For situations where rapid removal and replacement...

Страница 11: ...not observed there is a risk of overheating as units with the reverse airflow will be drawing in air which has already been heated by the PLMs The PLM is equipped with a sophisticated tempera ture se...

Страница 12: ...performs a diagnostic routine on the internal circuitry The fans will run at high speed for a short period before dropping to idle speed and the power symbol in the power switch will change from red...

Страница 13: ...Processing via the Lake Controller PLM Edition software includes selecting the basic PLM configuration including input mixers input format analog or digital etc crossover configuration and output rout...

Страница 14: ...l PLM Addendum for more information Once the software is installed the application can be launched by clicking the desktop icon created during the install process in the usual way Full details of how...

Страница 15: ...he example given is for configuring a four channel PLM to drive a 3 way loudspeaker system with sepa rate HF MF and LF drivers plus a separate Auxiliary output for feeding a subwoofer It assumes that...

Страница 16: ...ttom of the screen The contents of the scrolling bar will change From the options offered in the scrolling bar 11 double tap Default Modules the scrolling bar contents change again Double tap the Cont...

Страница 17: ...fed from Input 2 only at unity gain Tap the Return button to close the Aux Input Mixer window Note that Module B s processing is not required in this configuration 20 Open Module B s input mixer in t...

Страница 18: ...trips displayed represent the four power output channels as connected to the four Module 26 outputs in use In accordance with the settings made in Output Configurations in Step 22 the four strips repr...

Страница 19: ...of gain level adjustments are provided per Module output They are used to balance the mutual gain between frequency bands in a multi way set up and can be described as follows Manufacturer gain This...

Страница 20: ...eadroom of 10 dB or more for all channels The simplest way to accomplish this is to increase the input gain on the module Minimize the noise As a first step use a digital input signal AES or Dante whe...

Страница 21: ...SpeakerSafe Amp Gain Amp Gain Amp Gain Amp Gain Attenuator Mute Phase Rev AMP AMP AMP ISVPL ISVPL ISVPL ISVPL Output EQ LimiterMax RMS Peak Module Output Gain Level Phase Rev Mute Output EQ LimiterMa...

Страница 22: ...st filters are fitted behind metal covers To remove the covers loosen the thumbscrews located behind the handles Once detached the dust filter elements can be removed for cleaning See section 11 2 for...

Страница 23: ...nto MENU mode and the top page of the MENU tree is displayed Once in MENU mode the function buttons enable the user to navigate the menu tree and access most PLM Series operating functions See section...

Страница 24: ...previous screen up one level in the menu tree In METER mode pressing the EXIT key always returns the display to the HOME view 7 2 Rear Panel Overview Ser N o Removed CH 2 CH 1 CH 4 CH 3 CLASS 2 WIRING...

Страница 25: ...mpedance is 20 kOhms and the inputs can accept a maximum input level of 26 dBu Analog links Two latching XLR3M connectors are fitted adjacent to the analog input connectors These are paralleled to the...

Страница 26: ...sts Channel configuration is model dependant Speakon connectors The Speakon connector configuration differs on 2 and 4 channel PLM models On 4 channel models the power outputs are simultaneously avail...

Страница 27: ...is contained within a separate document the PLM Series Network Configuration Guide Primary connector Use this connector when the network is a simple star configuration consisting of individual Cat 5e...

Страница 28: ...ES EBU I O input link 2 x 3 pin XLR Analog 2 channel I O input link 4 x 3 pin XLR electronically balanced Output connectors Neutrik Speakon 2 x NLT4 or 4 Binding Posts pairs must be specified upon ord...

Страница 29: ...10 100 Auto Uplink 2 x RJ45 EtherCon Control and monitoring interface Via Ethernet for Lake Controller software Detachable mains cord Neutrik PowerCon 32 A Cooling Two fans front to rear airflow temp...

Страница 30: ...or accessories operation with faulty associated equipment or exposure to inclement weather conditions Damage due to normal wear and tear is not covered by the warranty Units on which the serial numbe...

Страница 31: ...of the defect Mark the Return Authorization number on the outside of the packing 3 Ship the product prepaid to 4 Lab gruppen AB Faktorv gen 1 SE 434 37 Kungsbacka SWEDEN Phone 46 300 56 28 00 Fax 46...

Страница 32: ...L ab gruppen A B S weden internationa L contact info L abgruppen com U S C O N T A C T info tc G A M E R I C A S com w w w l a b g r u p p e n c o m Operation Manual...

Отзывы: