Dolby Lake Controller User Manual PLM Edition Addendum

  

17

through for SpeakerSafe to monitor by selecting the 

“Force to configured” button.

5.4.6.3 Voice Coil Temperature

The third row of the Load Results table displays the 

estimated loudspeaker voice coil temperature from 

the LoadSmart test results. This is calculated from the 

LoadSmart verification results and Fingerprint data.

The  ALL  column  summarises  the 

temperatures in the form Min/Average/Max.

Thus 20/23/25 means that the channels 

being tested indicate calculated voice coil 

temperatures in the range 20° C to 25° C, with an 

average value of 23° C (assuming Celsius temperature 

units are selected).

5.4.6.4 speakersafe starting temperature

There are two options for selecting the starting voice 

coil temperature for SpeakerSafe operation. The first 

option is to accept the measured temperature. The 

second option is to set a specific temperature. The 

selection is made with via the soft buttons to the 

left of the display.

The range of voice coil temperatures from minimum 

to maximum is displayed to the right of the Accept 

measured temperatures button. Thus, in this example, 

20-25 would be displayed. If the range is acceptable 

and the Accept measured temperatures button is 

selected when SpeakerSafe is started, then these 

results will be the starting values for SpeakerSafe 

monitoring. 

Accept measured temperatures is the default condition 

for this button. Temperatures will be used unless 

modified as explained below.

In some cases the user may have reason to believe 

that the range of displayed voicecoil temperatures 

contains one or more anomalous results, possibly as a 

result of production spreads, or incorrect entry of cable 

data at the LoadSmart stage. In such cases, a starting 

temperature for SpeakerSafe monitoring may be 

entered manually. Tapping the left-hand button in the 

Set temperatures box sets the temperature currently 

displayed in the right-hand button. Tapping this button 

opens a numeric keypad allowing a temperature value 

to be entered. A SpeakerSafe starting temperature 

entered manually in this way effectively cancels out 

any errors and the entered values will be stored in 

the PLM for the next verification.

5.4.6.5 start speakersafe

Following acceptance of the calculated voice coil 

temperatures from the LoadSmart verification (or 

manual entry of a value), SpeakerSafe performance 

monitoring  may  be  initiated.  Press  the  Start 

SpeakerSafe  button.  The  status  of  the  load  on 

each power output channel will now be monitored 

continuously,  and  the  results  displayed  on  the 

Status and History tabs of the DLC, and also on the 

corresponding front panel screen of the PLM.

Note that SpeakerSafe will not run if a ‘Wrong’ result 

was obtained in LoadSmart verification for any of the 

PLM channels. The problem leading to the ‘Wrong’ 

result must be resolved before SpeakerSafe live 

monitoring can be run.

If SpeakerSafe is not started, a warning message 

will  be  generated.  The  SpeakerSafe  not  started 

warning will be displayed in the Event Log, and the 

message SPKSAFE INACT warning will be displayed 

on the PLM’s front panel and in the DLC PLM Edition 

software.

5.4.6.6 re-verify

If there is some reason to doubt the test results, or if 

there is an obvious reason for an unacceptable result 

which can be quickly rectified (e.g. a cabinet not 

plugged in), the load verifcation test may be re-run 

by pressing the Re-verify button.

operation  5

Содержание PLM Series PLM 10000Q

Страница 1: ...Rev 1 0 4 Item no UM PLM DLC ADD Dolby Lake Controller User Manual PLM Edition Addendum PLM Series Powered Loudspeaker Management systems...

Страница 2: ...5 2 2 Mute 11 5 2 3 Phase Reverse 11 5 2 4 Meters 11 5 2 5 Speaker data block 11 5 2 6 Amplifier data block 11 5 2 7 Mute and polarity enable 12 5 3 Control Tab 13 5 3 1 Power Control 13 5 3 2 Amplifi...

Страница 3: ...al Control Tab 21 5 7 1 Global Power Control 21 5 7 2 Global Temperature 21 5 7 3 Global LoadSmart 21 5 8 Global Events Tab 22 5 8 1 Log Entities 22 5 8 2 Sorting options 23 5 8 3 Filtering options 23...

Страница 4: ...ts as appropriate Note that the DLC PLM Edition software has all necessary functionality to control standalone Dolby Lake Processors and Dolby Lake legacy processors as well as PLM Series units The DL...

Страница 5: ...lace it in service We do however highly recommend reading through all manuals in their entirety As you become thoroughly familiar with all aspects of the PLM Series you may learn about features and op...

Страница 6: ...ve instructions on Configuring your Tablet PC for working with the Dolby Lake Controller PLM Edition software Installing the Dolby Lake Controller PLM Edition application on your Tablet PC Setting up...

Страница 7: ...en Installations In some situations the user may wish to have some of the same presets available in both versions To copy preset files from the existing old installation into the new DLC PLM Edition i...

Страница 8: ...n the Dolby Lake Controller PLM Edition software as well as via the PLM s front panel These include for example gain adjustment monitoring of output levels and temperatures and power control Basic per...

Страница 9: ...the Module icons selecting the Levels tab then tapping on the Lab gruppen info button An alternative method is from Main page button bar menu Tap the Modules button select a Module and then tap the I...

Страница 10: ...ut channel then this is displayed accordingly e g low low mid high ThePLM smetersarereproducedasverticalbargraphs Each channel strip provides an attenuation fader phase reverse button and mute button...

Страница 11: ...urrent meter Clip behavior is shown by a red light using a fast update rate to correctly indicate ballistics Two numerical displays are above the meter block The top display switches mode dynamically...

Страница 12: ...it and the channel number The frame name is assigned in Modules Label Lock Label Frame This name also displays in Frame block line 2 on the PLM front panel display The channel number corresponds to th...

Страница 13: ...ew See section 5 7 5 3 2 Amplifier Gain The Module Control tab displays a table showing the values currently set for Amplifier Gain The first row of the table shows the current Amplifier Gain settings...

Страница 14: ...erates a test signal which is applied to the power output stage Measurements are taken at the power output stage and the results computed for the speaker type using data from the LoadLibrary The Load...

Страница 15: ...d to initiate the LoadSmart verification Tap Yes to the confirmation button and all PLM power output channels assigned to the currently selected Module will have their loads checked The channels are m...

Страница 16: ...ute state No Model Fingerprint data is missing from the Module file selected Aborted A power output channel was in a protective state during the load verification process e g temperature fault The All...

Страница 17: ...malous results possibly as a result of production spreads or incorrect entry of cable data at the LoadSmart stage In such cases a starting temperature for SpeakerSafe monitoring may be entered manuall...

Страница 18: ...rameter to be displayed is selected by tapping on one of the buttons in the Select curve box below the graph The options are CombinedHeadroom Thiscurveisconstructed from all the individual parameters...

Страница 19: ...h parameter within the two minute sample period If Average is selected the curves will be of points representing the average of the values measured during the sample period 5 5 3 Channels The graph ca...

Страница 20: ...yed in the Global Events tab However here events are filtered to show only those relevant to the currently selected Module power output channels assigned to that Module and the Frame s incorporating t...

Страница 21: ...ly 5 7 2 Global Temperature The current ambient temperature the temperature of the air surrounding the cabinets may be entered on this tab Tapping on the blue button in the Ambient Temperature box ope...

Страница 22: ...available for displaying a user definable subset of the log Note that the data for the most recent event is repeated in the separate horizontal pane at the bottom of the table 5 8 1 Log Entities Seven...

Страница 23: ...all Modules on all frames on the system However it is possible to reduce the number of log entries to user definable subset with the filter options available on the right hand side of the table Note t...

Страница 24: ...trademarks of Lab gruppen AB PLM Powered Loudspeaker Management R SMPS LoadLibrary LoadSmart SpeakerSafe and ISVPL are trademarks of Lab gruppen AB Dolby Lake and the double D symbol are registered t...

Страница 25: ...L a b g r u p p e n AB S w e d e n i n t e r n a t i o n a L c o n t a c t i n f o L a b g r u p p e n c o m U S CONTACT i n f o u s t c e l e c t r o n i c c o m w w w l a b g r u p p e n c o m...

Отзывы: